2022-05-31 | Technical improvements, changes in design, printing- and other errors reserved. | BA_MIE.pdf |
Page 17 of 68
3.
Configuration
The device is configured via the graphical user interface of the integrated web interface.
To access the user interface, you need a standard PC/laptop with a network interface and the actual version of the installed web
browser. To connect the network interface of the device to the computer, you need a commercially available network cable.
The HTTP protocol is used for communication allowing a worldwide remote maintenance of the systems at various locations via
the Internet. Access protection is implemented by means of the password prompt.
The MIE is modular. Each module has its own configuration interface.
Default IP address of module A:
192.168.0.145
Subnet mask:
255.255.255.0
Default IP address of module B:
192.168.0.148
Subnet mask:
255.255.255.0
The expansion module MIM 3-02 also has its own IPTV address:
Default IP address of the expansion module:
192.168.0.148
Subnet mask:
255.255.255.0
The computer and the device must be in the same subnetwork. The network part of the IP address of the computer must be set to
192.168.0.x and the subnet mask must be set to 255.255.255.0.
The host part of the network address is required for the identification of the devices and can be assigned in the subnetwork only
once. You can allocate to the computer any not allocated host address between 0 and 255.
Hint:
Change the IP address and the subnet mask of your computer accordingly.
(e.g.: IP address:192.168.0.11 and subnet mask: 255.255.255.0)
Control panel > Network connections > LAN connection >Properties > Internet protocol version 4 TCP/IPv4 > Properties > Use the
following IP address:
Click OK to save.
Connect the PC to the RJ-45 Ethernet connector
Control
.
Start your web browser and enter the IP address of the connected module: e.g.: 192.168.0.145.