Operation instructions | MIE 8-00 | MIE 16-00 | MIE 32-00 | MIE 4-02 | MIE 8-02 | MIE 3-02 | MIE 6-02
Page 30 of 68
BA_MIE.pdf | Technical improvements, changes in design, printing- and other errors reserved. | 2022-05-31
3.4.7.
"Freeze" NIT version
Click on ADVANCED OPTIONS.
A dialog with options will open.
If programs change, then the NIT is recreated. In most countries, the end user does not notice, because the receivers automatically
read in the new NIT. However, in some countries (eg France) end users are asked to start a channel search.
If it comes to the case that one or more stations are weak to receive, then the NIT changes frequently and the end users are
always unnecessarily prompted to start a channel search.
In this case, the NIT version can be "frozen" (recommended for use in France).
Under NIT version, select Fixed.
Enter a version between 1 and 31.
Note:
If the station list really changes, the channel search must be done manually.
3.4.8.
OTA upgrade
To enable an
Over-the-Air
upgrade, two functions are available in the configuration:
•
Non-referenced PIDs can be manually added to the output modulators
•
Custom descriptors can be added to the NIT
Both are located in PHASE 2 under ADVANCED OPTIONS.
Note:
The function requires a valid license for “PID-Filtering” (see 3.8 on page 51).
Add non-referenced PIDs
Requirement:
In PHASE 1 a transport stream must already be selected which contains the unreferenced PID/PIDs.
Click in PHASE 2 on ADVANCED OPTIONS.
A dialog with options will open.