10. Until a plus (+) sign is shown in the right corner in the display of the master reader
i. Present the programming credential to the master reader.
ii. Present the programming credential to all slave readers
A plus sign (+) is shown in the upper right corner of the display when the master reader is
synchronized with every slave reader.
A plus sign (+) is shown in the upper right corner of the display when the master reader is syn-
chronized with every slave reader.
Maintenance/ administration of a SOLO-sys-
tem
If the system's users have DESFire EV2 fobs or cards, they will spread data from tha master
reader to the slave reader(s). To ensure that the database is quickly synchronized in all readers,
the slave readers can be updated manually. If the system has readers whose users do not also
pass the master reader, these readers must be updated manually.
If the system users do not have DESFire EV2 chips, all slave readers must be updated manually.
Synchronisation of all readers.
A programming tag is referred to the DESFIRE EV2 tag that was added to the system after initially
setting the master reader as master.
Until a plus (+) sign is shown in the right corner in the display of the master reader
i. Present the programming credential to the master reader.
ii. Present the programming credential to all slave readers
A plus sign (+) is shown in the upper right corner of the display when the master reader is syn-
chronized with every slave reader.
6 (9)
ManualA66 SOLO