ATEX Retractor System TANKO-RT/-RTS
68/121
Translation - Operating/installation instructions 2020/01
5 Installation
The resistance thermometer must be mounted as follows:
Figure 5.2-11: Resistance thermometer position
-
Release the retaining screw of the bracket for the limit switch
-
Mount the hose clamp with the resistance thermometer on the pneumatic pipe
-
Push the hose clamp with the resistance thermometer up to the clamp band of the limit switch
-
Tighten the hose clamp of the resistance thermometer
-
Tighten the retaining screw of the bracket for the limit switch
-
Connect the resistance thermometer to the switch amplifier and transmitter
(not supplied, see note “i” at the end of the section)
5. Check the function!
Resistance Thermometer
Limit switch “F”
Throttle check valve "E"
on the rear
Retaining screw bracket for
limit switch