TANKO®-CP Jet Cleaner
8 Faults Translation of the original operating/installation instructions 2016/10
69/77
8.2
Faults and Remedial Action
Fault
Cause
Remedy
The cleaning head does
not rotate and/or no fluid
is expelled.
Pressure for the cleaning fluid
is insufficient or no cleaning
fluid pressure.
Set the pressure and volumetric flow
rate to the standard values.
The strainer/filter or spray
holes are blocked.
Clean the strainer and filter.
Remove the device and check for
blocked spray holes or deposits.
Check the volumetric flow rate of the
device while the cleaning head is
removed.
Spraying head does not
rotate although enough
cleaning fluid is flowing
The plain or running surfaces of
the bearing have been
damaged.
Bushings and/or bearings are
seizing.
Move the cleaning head by hand.
In case of stiffness, internal damage may
have been caused by a knock or blow.
Replace faulty parts.
Deposits or damage in the
device
Check the bushings and/or bearings for
wear, clean or replace them.
Table 8.2-1: Operating Faults – Cause and Remedy
If the specified measures are NOT successful, please contact AWH.
In the event of return shipment (e.g. repair / servicing / return), a hazardous substance
declaration must be enclosed with the device in accordance with the Hazardous Substance
Directive (GefStoffV).