- Page - 7 -
ADVANCED WATER ENGINEERING, INC.
Indian Harbour Beach, FL
www.advancedwater.com
R.O. Membrane Element Replacement
1.
Follow steps 1 and 2 for pre-filter replacement.
2.Disconnect tubing and unscrew R.0. Housing end cap (Refer to Figure 2).
3.With a pair of pliers, grasp membrane end and pull out. A small amount of twisting may be
needed.
4.Clean housing, if necessary, with a mild chlorine solution.
Rinse away all chlorine
before
reassembly.
5. Wet the small 0-Ring on the end of the membrane element.
6. Insert into housing and firmly push while also rotating slightly, when pushing
in
you will feel
the membrane stop. With a little more pressure and turning action the membrane will
move
in
another 1/4”
-
3/8” of an inch. When this occurs the 0-Ring has been properly
seated.
7. Inspect housing 0-Ring for damage. If damaged, replace. Wet and install the 0-Ring on
the housing. Replace end cap and tubing.
8.
Follow Start-up procedure for restart unit.
Post Filter Replacement
1. Follow steps 1 and 2 for pre-filter replacement.
2. Disconnect tubing to filter.
3. Remove post filter from holding clips.
4. Remove end fitting.
5. Remove ALL Teflon tape from inlet/outlet post-filter fittings.
6. Rewrap with new Teflon tape.
7. Reinstall end fitting.
8. Place new post filter into clips.
9. Reconnect tubing to filter.
10.
Follow start-up procedure to restart unit. (Refer to previous page)