STORAGE TANK:
The storage tank assembly is used to store approximately 3 gallons of R.O.
water. The tank is pressurized with an air charge of 5 to
7
psi to force water back to the faucet.
Note:
If system is installed in unusually cold environment or the system is treating very cold
water, the air charge of the tank may need to be increased. This is due to contraction of the air
inside the tank when exposed to a low temperature environment. Conversely, if the system is
installed in high altitudes or very
high
temperatures, some air may need to be bled from the
permanent tank charge to achieve a 5-7 psi tank pressure. It is possible to operate the tank in a
horizontal position. The tank will discharge completely in any position. Although the tank has
3.2-gallon maximum capacity, the actual quantity of water that can be stored will be a function of
the incoming raw water pressure, T.D.S. and temperature. A 1/4” valve is provided to isolate the
storage tank from the system.
SERVICE CONNECTIONS
: The sink-top
faucet
is dedicated to dispense water from the
storage tank. It can rotate a full 360 degrees and can dispense water continuously or
intermittently. The faucet is equipped with an “air gap” feature to prevent a cross connection
between the potable water supply & waste water drain.
The
T-Link Ball
Valve is used to provide raw water feed to the R.O. systems and is designed to
attach to most under sink plumbing. Note that the R.O. must be fed COLD water only. Hot water
will permanently damage the system and void the warranty. The T-valve will also serve as a
shut-off to the system.
The drain saddle 1/4” is used for the R.O. waste water and can be easily installed on either PVC
or metal pipe drains.
A Tee with plug is available for Icemaker
connection and is found on the outlet side of the
post filter. Note the gray plastic plug located in this fitting. It is to be left in place if no auxiliary
connections are to be made. To remove the plug, cut the head off the plug,
un
screw the fitting
and push the plug through the grab ring (see section 6 for reference).