background image

 
MAGIC EEC 
 

ETI/EDI Converter

 

 

Hardware Manual 

 

Содержание 800890

Страница 1: ...MAGIC EEC ETI EDI Converter Hardware Manual...

Страница 2: ...91 90411 N rnberg GERMANY Phone 49 911 5271 0 Telefax 49 911 5271 100 AVT Audio Video Technologies GmbH All Rights reserved Reproduction in whole or in parts is prohibited without the written consent...

Страница 3: ...14 3 2 1 Ethernet interfaces LAN 1 LAN 2 14 3 2 2 TTL Relay interface 15 3 3 Clock interfaces 16 3 4 Network interfaces 17 3 4 1 E1 2 Mbit s interface Module Slot 1 and or 2 17 3 5 Power supply 18 3...

Страница 4: ...configuration monitoring SNMP and EDI input output The ETI interface has one G 703 G 704 input output each The system is configured via the PC software included in the scope of delivery and displays t...

Страница 5: ...possible 1 2 Safety The unit described has been designed to the latest technical parameters and complies with all current national and international safety requirements It operates on a high level of...

Страница 6: ...e device must be protected from water The device may only be installed in indoor rooms The device may only be cleaned with a dry cloth Any conversions or alterations to the unit or to parts of the uni...

Страница 7: ...he functions of the system are implemented in a 19 x 1U housing the dimensions are 434 mm x 44 5 mm x 260 mm MAGIC EEC can be used as a table top device or it can be mounted in 19 racks The 19 mountin...

Страница 8: ...raded to a full MAGIC SDC Switch Converter Options Monitoring output A second ETI module can be optionally equipped which means that an additional unrestricted ETI output is available This can be used...

Страница 9: ...ufficient cooling It is recommended to keep a spacing of ca 3 cm from the openings In general the ambient temperature of the system should be within the range of 5 C and 45 C These thresholds are spec...

Страница 10: ...ductor cross section of at least 2 5mm if it is mechanically protected or otherwise 4 0mm The following graphic symbols are located on the rear of the unit to indicate the correct and safe use After p...

Страница 11: ...characters 0 9 and 2 4 Front status LEDs The system has five LEDs for status indication When the device boots all five LEDs blink POWER green o OFF o ON SYNC yellow o OFF no alarm o ON configured refe...

Страница 12: ...a second ETI module or the Dual LAN Upgrade A redundant power supply is also available as an option 8 x programmable TTL In Outputs 8 x programmable Relays 2 x LAN Control EDI ETI Redundant power sup...

Страница 13: ...C SDC On the front side of the unit 5 LEDs for status indication are available The connectors for the interfaces are at the rear side of the unit MAGIC EEC front view MAGIC EEC rear view with optional...

Страница 14: ...er Additionally it can be used as EDI input For the LAN interfaces RJ 45 sockets are used Pin assignment ETHERNET INTERFACES LAN 1 LAN 2 Socket RJ 45 Pin Signal Electrical characteristics 1 TX Data ou...

Страница 15: ...puts Maximum voltage 3 3V Maximum current 10mA Relay interface Capacity of the relays Maximum voltage 48V Maximum current 200mA 2 TTL 2 output 3 TTL 3 output 4 TTL 4 output 5 TTL 5 output 6 TTL 6 outp...

Страница 16: ...Pin Signal Electrical characteristics 1 CLOCK IN Amplitude 2 0 to 5 5 V0P 2 GND Impedance 75 Ohm unbalanced Pin assignment CLOCK BNC SOCKET 10 MHz Pin Signal Electrical characteristics 1 CLOCK IN Ampl...

Страница 17: ...ETI converting if the EDI upgrade is available Pin assignment CLOCK BNC SOCKET 1 2 CLOCK Pin Signal Electrical characteristics 1 Data T3 in T3 out Amplitude 0 5 to 3 5 V0P Input Impedance 75 Ohm unba...

Страница 18: ...C 50 60 Hz auto adjusting max 30 W 3 5 2 Optional DC power supply socket Only use the 5 V DC power supply provided by AVT Pin assignment 5 V power supply socket Socket KYCON KPJ S4 Pin Signal Electric...

Страница 19: ...interfaces E1 ETI 2 048 MHz G 703 G 704 LAN EDI 10 100 Base T RJ45 Standards ETSI ETS 300 799 ETI ETSI TS 102 693 EDI Control interfaces 2 x Ethernet 10 100 Mbit s o Optional Dual LAN Upgrade 8 x TTL...

Страница 20: ...230 V Power max 30 W Redundant external power supply opt DC 5 V Power max 30 W Power consumption Typ 15 W max 30 W Dimensions W x H x D 434 mm x 44 5 mm x 260 mm Weight Ca 2 4 kg Further Information...

Страница 21: ...nverter Upgrade 800895 N 1 Redundancy Upgrade 430598 Dual LAN Upgrade 802034 Redundant Power Supply Upgrade 802035 5 2 Scope of delivery MAGIC EEC o 1 x external power supply adapter o 4 x Self adhesi...

Страница 22: ...ly please note down the factory number of the unit as well as the software version that you use The factory number is visible in the software under Administration Registration If you bought the system...

Страница 23: ...onment and health The device contains valuable raw materials that can be recycled For proper recycling send the device to us AVT Audio Video Technologies GmbH Recycling Nordostpark 91 90411 N RNBERG G...

Страница 24: ...oHS incl amendment 2015 863 EU Restriction of the use of certain hazardous substances in electrical and electronic equipment RoHS Die bereinstimmungwirdnachgewiesendurchvollst ndigeEinhaltungfolgender...