Avonic AV-CM40 Скачать руководство пользователя страница 1

Avonic PTZ Camera 20x zoom

AV-CM40

www.avonic.com | User Manual | Version 1.42

Содержание AV-CM40

Страница 1: ...Avonic PTZ Camera 20x zoom AV CM40 www avonic com User Manual Version 1 42...

Страница 2: ...istribution or for any commercial enterprise without the prior written consent of Avonic Copyright 2022 AVONIC All Rights Reserved The information contained in this Manual is subject to change without...

Страница 3: ...TY 1 Models No AV CM40 W 2 Brand Name Avonic 3 Product Name PTZ Camera 20x Zoom White 4 Manufacturer Avonic Exportweg 11a 2645ED Delfgauw Netherlands 3 This declaration of conformity is issued under t...

Страница 4: ...Netherlands 3 This declaration of conformity is issued under the sole responsibility of the manufacturer 4 The object of the declaration described in point 1 is in conformity with the EMC2014 30 EU 5...

Страница 5: ...igned or intended for use in the diagnosis of disease or other conditions or in the cure mitigation treatment or prevention of any condition or disease Please consult your healthcare provider prior to...

Страница 6: ...rture Auto Exposure AWB Aperture White Balance BLC Black Light Control CMOS Complementary Metal Oxide Semiconductor DRC Dynamic Range Compression EV Exposure Value HD High Definition HDMI High Definit...

Страница 7: ...12 Atmospheric Conditions 12 Product Overview 13 Description 13 Features 13 Unpacking 14 Package Contents 14 Handling Precautions 14 Unpacking the Camera 15 Return Procedure 15 Mounting and Installat...

Страница 8: ...nsport and Storage 41 Disposal and Recycling 42 Troubleshooting 43 General 43 Power Issues 43 Image 43 No image 43 Abnormal image 43 Dithering or flickering image 43 Color issues 43 Autofocus Issues 4...

Страница 9: ...2 Pelco P Protocol and command List 59 Appendix B Dimensions 60 Appendix C CMOS Image Sensor Characteristics 61 White Flecks 61 Aliasing 61 Focal Plane 61 Flash Band 61 Flicker 61 User Manual www avon...

Страница 10: ...IT professionals who are responsible for operating the Product Document Structure The Manual is subdivided into the following Chapters 1 Introduction 2 Safety 3 Product Overview 4 Unpacking 5 Mounting...

Страница 11: ...oduct Handle the Product with care It is made of metal glass and plastic and has sensitive electronic components inside The Product can be damaged if dropped burned punctured or crushed or if it comes...

Страница 12: ...ble safety standards They could pose a risk of death or injury when connected Do NOT use damaged cables Do NOT power the Product in a moist wet environment Before you power the Product ensure the cabl...

Страница 13: ...ranty on this camera Features The Avonic CM40 camera has the following features Lens High quality glass lens 20x optical zoom and 54 7 horizontal field of view Low light High SNR CMOS combined with di...

Страница 14: ...of the Product No Quantity Description Avonic SKU 1 1 pc PTZ Camera AV CM40 W B 2 1 pc Remote Control AV CM40 RC 3 1 pc USB cable type A to type A AV USB20 AA 4 1 pc Power Supply 12V A AV CM40 PSU 5 1...

Страница 15: ...he seal of the sealed camera bag 5 Take the camera out of the bag Be sure to follow the Handling Precautions on page 14 while doing so 6 Install the camera following the steps as described in chapter...

Страница 16: ...ight product in the Product Datasheet for the exact weight Use a safety loop or drop protection that prevents the Product from falling if the mounting construction fails During mounting and installati...

Страница 17: ...h at the back of the camera to ON After connecting the camera to its Power Supply Unit the camera starts initializing by first rotating the Pan Tilt to the maximum top right position and then to the c...

Страница 18: ...l for more information on how to use the Remote Control Serial Connecting via RS 232 or RS 485 COM Port Settings In default working mode the camera can connect to a VISCA controller via a RS 232 or RS...

Страница 19: ...RS 485 Interface Connect the controller to the and at the back of the camera via the RS 485 cables as shown in the figure below Note that the color of the connecting cables red and black in the figure...

Страница 20: ...92 168 5 163 with admin for both the username and password The control parameters for the CM4x cameras are as follows IP Address 192 168 5 163 Username admin Password admin TCP or UDP port 1259 IP Net...

Страница 21: ...he camera and use of the OSD menu Figure 13 Remote Control The various options a through n are described below a Power 1 Press the Power button to turn on the camera If the position preset 0 has been...

Страница 22: ...o change the IR channel inside the camera to IR channel 2 The camera will confirm this on the screen d Select camera 2 on the remote control to control this camera Key Combinations Default IR address...

Страница 23: ...s been stored this position will be called after initialization Use ONLY presets between 0 9 when using the Remote Control For presets 10 or higher you need a serial or IP connection i PTZ Keys up dow...

Страница 24: ...itch the video format to1080p60 1 Switch the video format to 1080p50 2 Switch the video format to 1080i60 3 Switch the video format to 1080i50 4 Switch the video format to 720p60 5 Switch the video fo...

Страница 25: ...g F is the default setting If you set the switch to F you can set the video format via the OSD Menu or the WebGUI The highest video output quality 1080p60 setting 0 The lowest video output quality is...

Страница 26: ...t can be accessed within the camera to change specific functions that effect how the camera processes an image The OSD Menu is visible on the HDMI SDI USB and IP outputs The OSD menu can be accessed b...

Страница 27: ...ess to change settings Press MENU again to go back 2 SETUP Figure 18 OSD SETUP 1 Select the Protocol you want to use Auto VISCA or PELCO and set the Address If you are using you the VISCA address you...

Страница 28: ...w following parts these settings will be explained Figure 19 OSD CAMERA 3 1 EXPOSURE Figure 20 OSD EXPOSURE If you click in the field after the option mode you will see that you have the following Exp...

Страница 29: ...era Settings Auto Expo BLC ON Flicker Set up your camera so that it can handle the flickering of artificial lighting in the space where it is operating The options are 50Hz 60Hz and OFF G Limit Gain l...

Страница 30: ...articular helpful setting when the light conditions are challenging The differences should be clearly visible in dark parts of the image as they will become lighter more grey as the level of DRC incre...

Страница 31: ...Red Gain Tuning increase or decrease red BG Tuning Blue Gain Tuning increase or decrease blue RG Finetuning the color red BG Finetuning the color blue Saturation How saturated the image s colors are...

Страница 32: ...cts the contrast of the picture The higher the number the more contrast you will get 3 4 FOCUS Figure 25 OSD FOCUS Focus Mode Auto The camera determines the focus position by itself and will adjust to...

Страница 33: ...ings are as follows NR 2D Used for still standing objects NR 3D Used for moving objects Dynamic Hot Pixel A dynamic hot pixel is a defective pixel which look much brighter than they should and will so...

Страница 34: ...nother preset when you use your remote controller Preset Pan Tilt and Zoom Speed This mode affects the speed to which the camera is switching from one preset to another when you use your remote contro...

Страница 35: ...t the DHCP to ON or OFF or you can set the IP Address 7 VERSION Figure 31 OSD VERSION No changes can be made This is to view the MCU Camera and AF Version you have 8 RESTORE DEFAULT Figure 32 OSD REST...

Страница 36: ...gin screen appears 3 Enter admin for both the User Name and Password 4 Click LOGIN to continue If DHCP is enabled and no DHCP server is available the camera will automatically appoint an IPv4 link loc...

Страница 37: ...ETWORK Use the tabs on the NETWORK screen to define the appropriate Port Ethernet and DNS settings Port Settings Figure 35 WebGUI NETWORK Port Settings You can define specific ports for the different...

Страница 38: ...with specific permission levels and different username passwords combinations There are 2 levels of users administrators with access to all features and user 1 and user 2 with access to the preview a...

Страница 39: ...GUI SYSTEM Default Click on This will restore the factory defaults to perform a factory reset When completed the camera automatically reboots The camera will be ready for use again after the boot cycl...

Страница 40: ...camera is very dirty clean it with diluted neutral detergent Do not use any type of solvents which may damage the surface Usage Precautions Take the following precautions to ensure good image quality...

Страница 41: ...rap the camera in the original plastic bag and to place it in the protective foam Specific guidelines apply to the environmental temperature and humidity when operating and storing the camera See Oper...

Страница 42: ...uipment and its parts that have been discarded by the owner as waste without the intention of re use Avonic outsources the disposal and recycling of its E Waste camera materials to the Stichting Open...

Страница 43: ...ons of monitor match the specifications of the camera 4 Check if the Iris under Exposure settings is set to closed Abnormal image 1 Check the quality and length of the video cable 2 Check the cable co...

Страница 44: ...f the above mentioned problems check also our Appendix CMOS characteristics Control No self test PTZ cameras only and no power LED 1 Check the net power 2 Check the power supply Remote Controller does...

Страница 45: ...separate document that you can download on the product website Visca over Serial Connection Visca is based on RS232 Serial communications at 9600 bit s 8N1 no flow control VISCA uses a serial repeate...

Страница 46: ...the camera The camera will send you the return commands 4 If you see the returned commands in exception with UDP the camera has executed the command You can check this in the WebGUI of the camera Def...

Страница 47: ...ple below the camera is switched between Preset 1 Visca command 81 01 01 3F 02 01 FF and Preset 2 Visca command 81 01 01 3F 02 02 FF 1 Type the command in the Send box The command consists of the came...

Страница 48: ...al command parameters is accepted Command Buffer Full 90 60 03 FF Indicates that two sockets are already being used executing two commands and the command could not be accepted when received Command C...

Страница 49: ...Stop 8x 01 04 08 00 FF Far Standard speed 8x 01 04 08 02 FF Near Standard speed 8x 01 04 08 03 FF Far Variable speed 8x 01 04 08 2p FF Near Variable speed 8x 01 04 08 3p FF p 0 low F high Direct Focu...

Страница 50: ...rect Iris Position 8x 01 04 4B 00 00 0p 0q FF Manual and Iris Priority min p 0 q 0 max p 0 q C CAM Shutter Direct 8x 01 04 4A 00 00 0p 0q FF min p 0 q 0 max p 1 q 0 Reset 8x 01 04 0C 00 FF Gain Settin...

Страница 51: ...Picture Effect Setting Reset 8x 01 04 3F 00 pp FF Set 8x 01 04 3F 01 pp FF CAM_Memory preset Recall 8x 01 04 3F 02 pp FF pp Memory Number 0 to 127 On 8x 01 04 61 02 FF CAM_LR_Reverse Off 8x 01 04 61...

Страница 52: ...Pan Position ZZZZ Tilt Position LimitSet 8x 01 06 07 00 0W 0Y 0Y 0Y 0Y 0Z 0Z 0Z 0Z FF Pan_tiltLimitSet LimitClear 8x 01 06 07 01 0W 07 0F 0F 0F 07 0F 0F 0F FF W 1 UpRight 0 Down Left YYYY Pan Limit Po...

Страница 53: ...FF Returned version in HEX for example 02 05 09 version 2 5 9 Red 8x 01 7E 010A 00 02 03 FF Tally Light RedON Green 8x 01 7E 010A 00 03 02 FF Tally Light GreenON CAM_TallyLight Cm7x only with license...

Страница 54: ...80p30 07 1080p25 08 720p30 09 720p25 0A 1080p59 94 0B 1080i59 94 0C 720p59 94 0D 1080p29 97 VideoSystem_Set CM40 series It is possible to set the video format but since the video format is dictated by...

Страница 55: ...y 90 50 0B FF Iris priority CAM_AEModeInq 8x 09 04 39 FF 90 50 0D FF Bright CAM_ShutterPosInq 8x 09 04 4A FF 90 50 00 00 0p 0q FF pq Shutter Position CAM_IrisPosInq 8x 09 04 4B FF 90 50 00 00 0p 0q FF...

Страница 56: ...80x720p25 90 50 0A FF 1920x1080p59 94 90 50 0B FF 1920x1080i59 94 90 50 0C FF 1280x720p59 94 90 50 0D FF 1920x1080p29 97 VideoSystemInq CM40 series It is possible to set the video format but since the...

Страница 57: ...38 FF 90 50 03 FF Manual Focus CAM_FocusPosInq 8x 09 04 48 FF 90 50 0p 0q 0r 0s FF pqrs Focus Position 90 50 00 FF Auto 90 50 01 FF Indoor mode 90 50 02 FF Outdoor mode 90 50 03 FF OnePush mode CAM_W...

Страница 58: ...FF Address 0x00 0x03 0x00 Preset ID SUM Clear Preset 0xFF Address 0x00 0x05 0x00 Preset ID SUM Call Preset 0xFF Address 0x00 0x07 0x00 Preset ID SUM Auto Focus 0xFF Address 0x00 0x2B 0x00 0x01 SUM Man...

Страница 59: ...ddress 0x00 0x03 0x00 Preset ID 0xAF XOR Clear Preset 0xA0 Address 0x00 0x05 0x00 Preset ID 0xAF XOR Call Preset 0xA0 Address 0x00 0x07 0x00 Preset ID 0xAF XOR Auto Focus 0xA0 Address 0x00 0x2B 0x00 0...

Страница 60: ...Appendix B Dimensions User Manual www avonic com 60...

Страница 61: ...le of a sinusoidal function In this example the dots represent the sampled data and the curve represents the original signal Because there are not enough sampled data points the resulting pattern prod...

Страница 62: ...Avonic PTZ Camera 20x zoom AV CM40 Version 1 42 March 2022...

Отзывы: