The following instructions will help you install your 

MergePoint service processor manager. Should you require 

further assistance, please contact Avocent Technical Support. 

1

Rack mounting or placing the MergePoint SP 

manager 

When installing the MergePoint SP manager in a rack, 
note the MAC address printed on the bottom label of the 

appliance. 

2

Connecting power to the MergePoint SP 

manager

Verify the appliance power switch is off. For AC models, 
plug the power cord into the appliance and plug the other 
end into a grounded AC power source. For DC models, 
wire the terminal block to separate DC power sources. 
Turn on the power switch. For more information on wiring 
DC models, see the MergePoint SP53XX SP Manager 

Installer/User Guide.

NOTE: 

For appliances with two power supplies, connect 

each supply to a separate power source.

3

Connecting to the network

Connect an Ethernet cable from the primary 
10/100/GE (Gigabit Ethernet) port to the network. To 
confi gure a secondary 10/100 Ethernet port, including 

setting up failover, see the installer/user guide.

4

Confi guring the MergePoint SP manager IP 

addresses

The MergePoint SP manager requires an IP address 
before use. The MergePoint SP manager ships as a DHCP 
client, and can obtain an IP address from a DHCP server. 

If you are using a DHCP server, proceed to step 5.

-or-

If your network environment does not have a DHCP server 
or if the DHCP server is not available or times out, two 
default IP addresses are automatically designated for eth0 
and eth1. The IP addresses are 192.168.0.10 for eth0, 
and 192.168.0.20 for eth1. If you wish to designate an IP 
address, confi gure the appliance via a DSView

®

 3 server 

or the Command Line Interface (CLI).

To confi gure using the DSView 3 software:

Use the DSView 3 Add Units Wizard to add the 
MergePoint SP manager to the DSView 3 software. 
During the Add Unit Wizard, select 

Unit does not have 

IP address

. Enter the MergePoint SP manager network 

information and select the unit MAC address from the list.

To confi gure using the CLI:

Connect a terminal or a server running a terminal 
emulation program to the console port using the included 
DB-9 to RJ-45 crossover cable.

a. Open a terminal session with the settings: ANSI 

emulation, 9600, 8, N, 1, no fl ow control. 

b. Log in as 

root

 and use the default password 

Sydney

.

c. Enter the 

passwd

 command and change the root 

password.

WARNING: 

For maximum security, the default username 

and password should be changed.

d. Enter the 

cli

 command. 

e. Enter network specifi c information with the 

set

 

command. For example, to activate the primary 
Ethernet interface, confi gure a static IP address and 

basic network parameters, enter: 

    

set network interface eth0 method static address <IP_

address> netmask <netmask> gateway <gateway>

NOTE:

 Pressing the Tab key twice will list available 

command variables. 

f. Enter the 

commit

 command to save changes.

g. Enter the 

quit

 command to exit the cli utility.

h. Log out.

5

Using the confi guration wizard

The fi rst time you log in to the MergePoint SP manager, 

the confi guration wizard window opens automatically. 

The wizard allows you to confi gure appliance settings 

such as alias, default user account, discovery range, 

appliance network, provisioning, SNMP and host table 

among others. These settings can be saved as an XML 

fi le for future use when you confi gure an appliance using 

the wizard. See the MergePoint SP53XX SP Manager 

Installer/User Guide for more information.

6

(Optional) Connecting service processors to the 

MergePoint SP manager

NOTE: 

The MergePoint SP manager can administer 

service processors connected to the same physical 

network it resides on. For maximum security, connect 

service processors directly to the MergePoint appliance 

private network ports. 

Connect a standard Ethernet cable from any private 

Ethernet port on the MergePoint appliance to any of the 

following types of Ethernet ports:

•  A dedicated Ethernet port on a service processor

•  A dedicated Ethernet port on a blade server 

managing multiple blade service processors

7

Confi guring the service processor

Using your service processor’s documentation, enable the 

service processor and assign it an IP address.

CAUTION:

 Depending on your system confi guration, 

service processors that are not connected directly to 

the MergePoint SP manager may be accessible from 

a public network. To prevent unauthorized access, it is 

recommended that you change the preset username and 

password for the service processor. 

8

Confi guring the DSView 3 software

If you wish to host service processors on multiple 

subnets, you can confi gure them through the DSView 3 

software or MergePoint SP manager web interface. See 

the installer/user guide for details.

9

Confi guring private subnets

At least one subnet is required to allow SPs connected 

to the private Ethernet ports to communicate with the 

MergePoint SP manager.

Confi gure an IP address for the private subnet. The 

MergePoint SP manager uses this IP address to 

communicate with the service processors. 

After confi guring a private subnet, it is recommended that 

the administrator assign each SP an IP address within 

the range of the private subnet. If an SP is not assigned 

an address with the range of the private subnet, the 

MergePoint SP manager attempts to contact the SP using 

the primary interface IP. 

Multiple private subnets are not required, but may be 

used. 

NOTE:

 The MergePoint SP manager does not normally 

route between the private subnets. The private subnets 

are an added layer of security and separation between 

connected service processors. 

(Continued on reverse side)

 

QUICK INSTALLATION GUIDE

 MergePoint

®

SP5324/SP5340 

Service Processor (SP) Manager

MergePoint SP5340 Service Processor Manager Shown

Network

Ethernet

Remote User

2

3

4

Console User

Blade or Service Processor (SP)

5

Technical support and fi rmware or software updates: 

www.avocent.com

      

Product manuals: 

www.avocent.com/manuals

 

Avocent, the Avocent logo, MergePoint and DSView are registered trademarks of Avocent Corporation or its affi liates in the U.S. and other countries. All other marks are the property of their respective owners. ©2008 Avocent Corporation. 

 590-838-501C

Отзывы: