Emerge

®

 EMS

Installer/User Guide

Содержание Emerge EMS1000MP Series

Страница 1: ...Emerge EMS Installer User Guide...

Страница 2: ...INSTRUCTIONS This symbol is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance...

Страница 3: ...er Guide Avocent the Avocent logo The Power of Being There and Emerge are registered trademarks of Avocent Corporation All other marks are the property of their respective owners 2005 Avocent Corporat...

Страница 4: ...l interference to radio or television reception However there is no guarantee that harmful interference will not occur in a particular installation If this equipment does cause interference to radio o...

Страница 5: ...ocations 5 Mounting 6 Making Standard Connections 8 Connections at the Transmitter 8 Connections at the Receiver 13 Making Cascade Connections 16 Chapter 3 Operations 23 Indicators 23 Adjustments 24 B...

Страница 6: ...iv Emerge EMS Installer User Guide...

Страница 7: ...connected 14 Figure 2 13 Connecting the link cable to the receiver unit 14 Figure 2 14 Connecting the power adaptor to the receiver unit 15 Figure 2 15 Connecting the power adaptor to the power cord 1...

Страница 8: ...vi Emerge EMS Installer User Guide...

Страница 9: ...ing Thanks to sensible design and no nonsense build quality you can expand your installation at any time using additional Emerge EMS units to keep pace with your project Configuration Possibilities Th...

Страница 10: ...is capable of directly feeding up to four EMS1000MP R receivers Each receiver supports two remote screen and speakers sets but additionally can also drive a further three receivers and their respectiv...

Страница 11: ...MP R receivers as only they are equipped with the necessary LINK OUT cascade port Using the LINK OUT port the video and audio signals are transferred via UTP cabling to the next receiver This receiver...

Страница 12: ...re on the same phase For best results they should be on the same circuit The primary means to cease operation of the units is to remove the power adaptor lead Ensure that the power adaptor is position...

Страница 13: ...ions Ensure that the transmitters are as close as possible to the source PC system and the receivers are similarly close to the display units Use video connection cables that are correctly shielded an...

Страница 14: ...e Velcro strips not supplied Using the supplied self adhesive feet Apply the supplied self adhesive rubber feet to the underside corners of the Emerge EMS units Using the rear mounting slot The slot a...

Страница 15: ...ide the unit into the required rack position 4 The rack mount chassis has a series of holes in its floor that are spaced to accommodate the screws on the unit s lower edge Ensure that the screws corre...

Страница 16: ...d Audio from the Source PC System 1 Attach a video cable of suitable type and length fully shielded with 15 way male D type connectors at both ends 6 feet or less to the socket labeled RGBHV IN on the...

Страница 17: ...See below or Make a cascade link to another transmitter unit Please refer to the section Making Cascade Connections To Connect Cascaded Transmitters 1 Attach the video cable from the monitor to the s...

Страница 18: ...ge EMS1000P transmitter There should be a click when the cable is fully inserted and locked in place To Connect the Link Cable s The links between the transmitter and receiver units are made using bet...

Страница 19: ...mitter There should be a click when the cable is fully inserted and locked in place 2 Attach the connectors of the remaining link cables to the sockets labeled L2 OUT to L4 OUT as required In all case...

Страница 20: ...thed mains socket To Connect the Power Adaptor NOTE Please read and adhere to the electrical safety information given within the Safety Precautions section of this guide In particular do not use a 2 w...

Страница 21: ...of ports provide identical signals and their connection procedures are the same 1 Attach the video cable from the display unit to the socket labeled RGBHV OUT on the Emerge EMS receiver 2 Attach the...

Страница 22: ...ade to the initial receiver using the LINK OUT port Emerge EMS1000MP R models only then the overall length of the link cables used must be reduced For further information please refer to the section M...

Страница 23: ...tor and attach its output connector to the socket labeled PWR on the Emerge EMS receiver 2 Insert the IEC connector of the supplied power cord into the corresponding socket of the power supply 3 When...

Страница 24: ...h count the number of cascade connections between the Primary Transmitter and the final receiver in that branch The effects of cascade connections on overall branch link lengths are as follows Table 2...

Страница 25: ...m Overall maximum length for link with 1 cascade 800 feet 250 m Standard link Standard link Cascade 1 Transmitter Receiver Receiver Receiver Branch 1 Branch 2 Cascade 1 Cascade 2 Cascade 2 Cascade 3...

Страница 26: ...ansion at the transmitter end is achieved using the video and audio output ports The signals from these ports are connected to the video and audio inputs of the next transmitter and so on Emerge EMS10...

Страница 27: ...ereo audio cable shielded with three way 3 5mm jack plugs at both ends to the socket labeled on the primary Emerge EMS transmitter 4 Attach the other end of the stereo audio cable to the socket labele...

Страница 28: ...particularly at higher resolutions These effects are called skew and result from differing delays on the red green and blue color signals as they travel to the receivers Each Emerge EMS1000MP R receiv...

Страница 29: ...er 2 At the other end of the cascade link cable attach the connector to the socket labeled LINK IN on the secondary Emerge EMS1000MP R receiver In all cases there should be a click when the cable is f...

Страница 30: ...22 Emerge EMS Installer User Guide...

Страница 31: ...000P models Indicators All Emerge EMS units are equipped with two indicators to confirm operation and if necessary assist with quick troubleshooting of potential problems The indicators are located on...

Страница 32: ...e background NOTE Both video outputs are equally affected by your brightness and or sharpness adjustments To Display a Suitable High Contrast Image Open a word processor type the capital letter H or M...

Страница 33: ...t is possible to correctly align all three colors The effects of skew are easiest to view and adjust when distinct red green and blue elements in close proximity are present within the screen image An...

Страница 34: ...lay to either of its colors However if the unit has been previously used and adjusted then you may need to relocate the zero point There are no setting markers around the two skew dials and the dial i...

Страница 35: ...Adjustment Dials 1 Turn the SKEW RG dial clockwise or counterclockwise until you observe that the red and green colors are aligned 2 Turn the SKEW GB dial clockwise or counterclockwise until you obse...

Страница 36: ...28 Emerge EMS Installer User Guide...

Страница 37: ...ssue should develop follow the steps below for the fastest possible service To resolve an issue 1 Check the pertinent section of the manual to see if the issue can be resolved by following the procedu...

Страница 38: ...unit is distorted or shadows appear to the right of displayed objects Adjustments are required to compensate for the length of the twisted pair cable being used If video problems persist Please refer...

Страница 39: ...power in 15 receiver video audio out 13 transmitter cascade 18 transmitter link out 10 transmitter power in 12 transmitter video audio in 8 transmitter video audio out 9 D Displays connection at rece...

Страница 40: ...fety precautions 4 Self adhesive feet 6 Sharpness adjustment 24 SHARP dial 24 Skew compensation adjustment 25 27 zeroing the dials 26 Slot rear mounting 6 Speakers connection at receiver 13 connection...

Страница 41: ...nt Asia Pacific Singapore Branch Office 100 Tras Street 15 01 Amara Corporate Tower Singapore 079027 Tel 656 227 3773 Fax 656 223 9155 092705 00UG Avocent Canada 20 Mural Street Unit 5 Richmond Hill O...