Cyclades ACS 6000 Advanced Console Server Installation/Administration/User Guide
Ports Configuration
Physical Ports
An administrator can enable and configure serial ports and auxiliary ports. On the serial ports
screen, you can enable serial ports, specify the connection profile (CAS, Dial-In or Power) based
on the type of connected device, optionally configure the port with a Cisco pinout if required and
configure communication settings. On the auxiliary ports screen, you can enable the auxiliary port
and configure it based on the type of connected device.
To enable or disable, change the pinout, select a Serial Profile and configure
communication settings for one or more serial ports:
1.
Select
Appliance Settings - Ports - Physical Ports
-
Serial Ports
. The
Serial Ports
screen
appears.
2.
Click the port number or the checkbox for each port you want to configure.
3.
Click
Edit.
4.
Select
Enabled
or
Disabled
from the Status menu.
5.
(Optional) To change the default pinout when a Cisco cable is connected to the selected
port(s), select
Cisco
from the RJ-45 pinout menu.
6.
For port(s) connected to the console of a target device, select
CAS
from the Serial Profile
menu.
7.
For port(s) connected to a modem, select
Dial-in
from the Serial Profile menu.
8.
For port(s) connected to a PDU, select
Power
from the Serial Profile menu.
9.
To reconfigure the connections settings to match the device(s) connected to the selected
port(s), make the needed changes in the Communication Settings area of the screen.
10. Click
Save
, then click
Close
.
To enable and configure the auxiliary port for a connected modem or PDU:
If an internal modem is not already installed at the factory, you can connect an external modem or a
PDU to the AUX/Modem port. Perform this procedure to configure the auxiliary port.
1.
Select
Appliance Settings - Ports - Physical Ports
-
Auxiliary Ports
. The Auxiliary Ports form
appears.
2.
Click the port number. The Aux Ports Settings form appears.
3.
Select
Enabled
or
Disabled
from the Status menu.
4.
If the port is connected to a PDU, select
Power
from the Serial Profile menu.
5.
If the port is connected to a modem, select Dial-in from the Serial Profile menu.
6.
Click
Save
, then click
Close
.
Содержание Cyclades ACS 6000
Страница 8: ...vi Cyclades ACS 6000 Advanced Console Server Installation Administration User Guide...
Страница 10: ...viii Cyclades ACS 6000 Advanced Console Server Installation Administration User Guide...
Страница 12: ...x Cyclades ACS 6000 Advanced Console Server Installation Administration User Guide...
Страница 80: ...68 Cyclades ACS 6000 Advanced Console Server Installation Administration User Guide...
Страница 88: ...76 Cyclades ACS 6000 Advanced Console Server Installation Administration User Guide...