IntelliTrack Module
Operations Guide
AvL Technologies
| Proprietary – Content is Subject to Change without Notice
pg. 21
IntelliTrack Step Track Peak
Power El Offset
4
The elevation offset position of the current peak power detected by
StepTrack. (from the model position with any previous offsets added)
IntelliTrack Step Track State
4
The current state that StepTrack is running
IntelliTrack Target Azimuth
0
The azimuth position of the current IntelliTrack target. (IntelliTrack only,
no offsets applied)
IntelliTrack Target Elevation
0
The elevation position of the current IntelliTrack target. (IntelliTrack
only, no offsets applied)
4.3. Module Windows
4.3.1. Device Window
A Device Window is not needed for monitoring operation and is not included in the software.
4.3.2. Device Control Window
A Device Control Window is not needed for monitoring operation and is not included in the software.
5.
Issues and troubleshooting
Issue
Description
Corrective Action
Target profile not set
to run IntelliTrack
IntelliTrack State
sensor
output shows “
Idle
” after
Acquire or Track commands
are issued and the system
does not track
Check that IntelliTrack is set as the
Tracking
Method
and
Run Track After Acquire
is set
to “Yes” in the target configuration
Target profile not set
to skip standard
acquisition process
System attempts to acquire
and peak at nominal
geosynchronous location
before running IntelliTrack
scans
Check that the
Skip Acquire Sat State
target configuration item is set to “Yes”