IntelliTrack Module
Operations Guide
AvL Technologies
| Proprietary – Content is Subject to Change without Notice
pg. 10
Reference Satellite
Mode
4
Choice
Yes, No
Flag indicating that reference profiles
should be used if a heading is needed.
Run Track After
Acquire
4
Choice
Yes, No
Flag indicating that the Tracking Module
should run after a successful acquire
Run Track After Peak
4
Choice
Yes, No
Flag indicating that the Track Command
should run after a successful peak
command.
Run Track on Startup
4
Choice
Yes, No
Flag indicating whether the track command
should be run on start up
Skip Acquire Sat State
4
Choice
Yes, No
Flag indicating whether the acquire state
should be performed before entering track
mode.
Note – This must be set to “Yes” to use
IntelliTrack
Tracking Method
4
Choice
None, Intellitrack
Module, other
installed tracking
modules
Track Method to use after an Acquisition
has completed. Set to IntelliTrack Module.
IntelliTrack Model Clear
– Whether or not to clear all IntelliTrack tracking memory for the
current target profile when not tracking. This will clear the IntelliTrack model any time the
module enters or exits tracking.
IntelliTrack Signal Gradient Threshold
– This
parameter controls the maximum signal change
that will not cause a peaking decision error during step peaking. If this value is exceeded by the
Current Signal Gradient, then the peaking delay time will be reset. Setting this parameter to 0
will disable its functionality.
IntelliTrack Noise Noise Threshold
– This
parameter controls the maximum signal (noise)
change that will cause a peaking decision error during step peaking. If this value is exceeded by
the Current Signal noise, then the peaking delay time will be reset. Setting this parameter to 0
will disable its functionality.
Reference Profile 1
– This is the target profile to be used for a SatTant. Using a reference profile
will produce a more accurate heading than using the compass systems incorporated into the
antenna.
Note – A Reference Profile must always be used with the IntelliTrack Module. Refer to
the main user manual for information regarding Reference Profile configuration.
Reference Profile 2
- This is the target profile to be used for a SatTant if acquisition on
Reference Profile 1 is unsuccessful.
Note – A Reference Profile must always be used with the
IntelliTrack Module. Refer to the main user manual for information regarding Reference Profile
configuration.