40
© 2008 Directed Electronics. All rights reserved.
When programmed to the latched output the status will only stay active
for 10 minutes. Both outputs activate 10 seconds after remote start.
9 ANTI-GRIND
ON
:
With the anti-grind On (default) the ground-when-locked output will be
active during remote start operation. This activates the optional starter
kill relay and prevents the customer from re-cranking the car with the
key, when doing key takeover. If accessories such as a voice module
or window module are added to the unit, it may be necessary to use
the two-honk setting to program this feature OFF.
10 WAIT-TO-START TIME
OFF
/15, 30, 45 SECONDS:
Default is the “Wait-to-Start” input control wire, or programmable to
ignore the input control wire by a delay of 15, 30, or 45 seconds.
11 RUN TIME (TIMER MODE)—
0
, 3, 6, 9 MINUTES:
Selects the time in minutes that the system will operate the engine until
the system “times out”. This is the maximum operation period and the
system may be shut down using a shutdown at any time.