1. Detector Installation

The Panachrome

+

 10mm 3D/2D detectors can be fitted to centre-opening or side-opening doors. For the visual indicators 

to be effective, the system can be installed in dynamic mode, where at least one of the detectors is fixed to a moving 
door or in static mode. TX detector must be fitted to left side of lift when viewed from landing.

Memco Panachrome

+

2D/3D 10mm Profile

Installation Guide

Ref No. G510 850GB Version 2

Installation Notes - 3D

When installing a Panachrome

+

 3D system, the following 

precautions must be observed for trouble-free operation:

1. 

Always mount the detectors as close to the door edge 
as possible.

2. 

Sight-Guards cannot be used with Panachrome

+

 3D 

detectors.

3. 

For opening exceeding 1200mm, it is recommended 
that ‘On at closing’ mode is used.

4. 

The detectors must be set no more than 10mm apart 
when the doors are fully closed. The detectors must be 
aligned to within 

±

8mm of the detector centre line.

5. 

3D mode settings are set using the Controller menu 
under 3D.

Installation Notes - 2D/3D

1. 

Check that the door itself is grounded to the lift

2. 

Use a P-clip either side of the pluggable connectors, to 
reduce the risk of plug and socket separating

3. 

Do not shorten Memco cables by cutting them.

4. 

Position the detectors on the doors approximately 3mm 
above the door sill

5. 

Mark or spot through the 3 fixing holes. See Fig 1.

6. 

Remove the detectors from the door before drilling

7. 

Drill the 3 fixing holes in the door using a 3mm drill

8. 

Screw the detector to the door using the No.6 self-
tapping counter sunk screws provided

9. 

Finally, check that the detectors are aligned with each 
other.