INSTALLATION

Dynamic Installation

 

+

Position each detector 5mm above the sill

 

+

Ensure that the detectors are aligned level and straight with each other

 

+

Please refer to the lift/elevator OEM manual for the correct installation of the mechanical safety edges

 

+

Secure the cables with the P-clips and screws provided.  Ensure there are no tight bends and the cables are not 
stressed or stretched as the doors move

Ref No. 745 850 (ML) V01

Fig 1:  Profiles

Connect with 841 Controller

Pana40 Plus edges must be installed with an 841 Pana40 Plus Controller.  Refer to the Controller Installation Guide for 
details on configuration.

2in1 : 28mm profile 

(745 050)

2in1: 20mm profile (755 200) 
3in1: 20mm profile (775 200)

2in1: 22mm profile (755 220) 

3in1: 22mm profile (775 220)

2in1: 25mm profile (755 260) 

3in1: 25mm profile (775 260)