![Avidyne Entegra EX5000 Скачать руководство пользователя страница 57](http://html.mh-extra.com/html/avidyne/entegra-ex5000/entegra-ex5000_installation-manual_3031518057.webp)
EX5000 Release 8.2.2 Installation Manual P/N 600-00073-001 Rev 02
- 57 -
Table 22: ART-2000 Sensor Configuration Options
Option
Value
Notes
Park Position
Last position
Set the park/startup position for the radar antenna tilt angle.
Full up
Centered
Full down
Beam Width
10” Antenna
12" Antenna
10
°
8.1
°
Defines the Width and Height of the radar sweep graphical depiction
on the EX5000 radar display.
Beam Height
0.0
o
– 19.5
o
Enable Gain Control
Check/Clear
Enables R/T variable gain control to be commanded from the
EX5000.
Enable VP
Check/Clear
When checked, enables Radar Vertical Profile mode.
Enable Auto-Tilt Control
Check/Clear
When checked, enables Radar auto-tilt mode.
Primary Indicator (1)
Check/Clear
When checked, enables EX5000 control of radar functions.
Disable Stabilization
Check/Clear
Disables EX5000 display of the “Stab Off” annunciation
Enable Automatic Standby
Check/Clear
When checked, enables the EX5000 to auto-command the radar to
standby when ground is sensed to be below 20 kts.
5.10.1 RADAR System Calibration
Calibrating the Radar R/T unit requires access to the Radar Calibration Page on the Entegra or
Envision EX5000 unit. This section explains how to access the calibration page and complete the
radar calibration.
Perform radar R/T calibration according to the procedures and specifications for the specific unit
installed in the aircraft.
Calibration can be performed after the Radar has been installed, setup and checked out per the radar
manufacturer’s instructions.
To calibrate the system:
1.
From the Maintenance Mode Page, select
Setup Radar
.
2.
From the Radar Setup page. access the Calibration Mode
3.
Perform the calibration according to the specifications in the R/T unit's Installation Manual.
4.
Press Enter to accept the new values.
5.
When you are done, press
Save
from the Radar Setup Page. Press
Cancel
to exit without saving
changes.
6.
Changes do not take effect until the MFD has been restarted. From the Maintenance Mode Page,
press
Restart System
.
Содержание Entegra EX5000
Страница 1: ......
Страница 64: ...EX5000 Release 8 2 2 Installation Manual P N 600 00073 001 Rev 02 64 Save Configuration ...
Страница 95: ...EX5000 Release 8 2 2 Installation Manual P N 600 00073 001 Rev 02 95 Appendix G Landscape Cutout Dimensions ...
Страница 96: ...EX5000 Release 8 2 2 Installation Manual P N 600 00073 001 Rev 02 96 Appendix H Portrait Cutout Dimensions ...
Страница 98: ...EX5000 Release 8 2 2 Installation Manual P N 600 00073 001 Rev 02 98 Appendix J Wiring Diagram GPS FMS ...
Страница 99: ...EX5000 Release 8 2 2 Installation Manual P N 600 00073 001 Rev 02 99 ...
Страница 101: ...EX5000 Release 8 2 2 Installation Manual P N 600 00073 001 Rev 02 101 Appendix L Wiring Diagram Traffic Sensors ...
Страница 102: ...EX5000 Release 8 2 2 Installation Manual P N 600 00073 001 Rev 02 102 Appendix M Wiring Diagram TAWS ...
Страница 103: ...EX5000 Release 8 2 2 Installation Manual P N 600 00073 001 Rev 02 103 Appendix N Wiring Diagram Radar Sensor ...
Страница 104: ...EX5000 Release 8 2 2 Installation Manual P N 600 00073 001 Rev 02 104 Appendix O Wiring Diagram Engine Sensors ...