Replacing a Power Supply (5U)
56
n
Make sure you have a replacement before removing a failed component to maintain proper airflow.
When the Engine power is left on, insert the new cooling module within two minutes after removing
the defective cooling module.
To remove a cooling module:
1. Identify the cooling module to be removed. If the module has failed, the fan fault LED will be lit
“5U Chassis Rear View Details” on page 12
).
2. Push down and hold the red release latch (callout 1 in the following figure) and pull the module
out by its handle (callout 2).
To insert a cooling module:
1. Position the cooling module so that the red release latch and handle are on the right-hand side.
2. Slide the cooling module into its slot until the latch clicks in place. The Engine will
automatically detect and make use of the new unit.
Replacing a Power Supply (5U)
In Avid NEXIS | E5 and Avid NEXIS | E5 NL, the power supplies are separate from the cooling
modules. These systems are designed to continue working with only one of the two power supplies.
n
Make sure you have a replacement before removing a failed component to maintain proper airflow.
When the Engine power is left on, insert the new power supply within two minutes after removing the
defective power supply.
To remove a power supply:
1. Identify the power supply to be removed. If the module has failed, the fan fault LED will be lit
amber.
2. Push the red release latch to the right and hold it (callout 1 in the following figure), then pull the
module out by its handle (callout 2).