Working with Play While Record
69
6. Enter the fully qualified domain name of the server running the Lookup service for the
Command workgroup.
7. Leave the port setting as is.
8. Select the Expected check box.
9. Click OK.
10. (Optional) If running multiple Lookup services, repeat steps
to add another server that is
running the Lookup service for the Command workgroup.
11. Click OK on the
Avid Workgroup Properties
window.
12. Click Yes, when prompted to restart all services.
n
For AMS up/down cross convert integration, autocue must be turned off when transitioning between
XDCAM 720p and 1080i clips. For Auto Switch Output Format, users also need to turn off autocue if
they plan to switch formats. This is because the AMS channel needs to be in an idle state—not
playing for instance—for it to switch formats.
Avid recommends having dedicated channels for specific resolutions.
Working with Play While Record
This section provides additional information to help clarify the existing Play While Record feature
when used with an AirSpeed video server, such as AirSpeed 5000 or AirSpeed Multi Stream.
After an item starts recording on the video server, it appears within the Command Inventory Panel
within approximately 10 seconds. When it appears in Command, users can open the item in the
Media Viewer to adjust the Mark In point, and then play the item.
n
This requires an available playback channel on the video server that is recording the item. A Mark
Out point is not required, only a Mark In timecode.