background image

Thank you for choosing UV Air Purifier C2. Please read this User  Manual 
carefully before use and maintenance and keep it properly for future reference.

User Manual

Version 1.1

Air Purifier

Model: C2 

Содержание C2

Страница 1: ...Thank you for choosing UV Air Purifier C2 Please read this User Manual carefully before use and maintenance and keep it properly for future reference User Manual Version 1 1 Air Purifier Model C2 ...

Страница 2: ......

Страница 3: ...1 Table of Contents I Device and Accessories Ⅱ Product Introduction Ⅲ Quick Use Guide Ⅳ Maintenance Ⅴ Safety Instructions Ⅵ Troubleshooting Guide Ⅶ After sales Service and Warranty Card 2 3 6 8 9 11 12 ...

Страница 4: ...ure 1 in the package If any shortage or damage Please contact suppliers or manufacturer immediately Figure 1 Packing List Main Unit including Filter x 1 User Manual including Warranty Card x 1 Thank you for choosing UV Air Purifier C2 Please read this User Manual carefully before use and maintenance and keep it properly for future reference User Manual Version 1 0 Air Purifier Model C2 ...

Страница 5: ... antibacteria mites killing deodorant insect prevention and UV Protection The super fine hole structure of Bamboo fiber make it have strong absorption and can absorb formaldehyde benzene methylbenzene ammonia and remove odor b HEPA Filter Purification 99 9 of the microscopic particles 0 3 microns and larger can be captured while pass through the HEPA filter It is highly efficient at tobacco smoke ...

Страница 6: ...ization Photocatalytic Degradation HEPA Filter Bamboo Fiber Bamboo Charcoal Eco friendly Filter Air Quality Grade Good Moderate Color Indicator Green Blue Yellow Red Filters Filter Weight 1 65kg 155mm Inner Dia 260mm outer Dia 300mm H Body Material ABS Aplicable Space 36 62 3m2 Purification Efficiency Super grade ηPM 7 2 m3 W h Super grade ηHCHO 3 m3 W h CADRPM 519 5m3 h CADRHCHO CCMPM P4 F4 CCMHC...

Страница 7: ...tion Outlet Inlet Product Main Body Figure 2 1 Top Cover Figure 2 4 Bottom Figure 2 2 Top View of Display Screen Figure 2 3 Air Quality Indicator Anti slip Pads 2 Product Parts Introduction Bottom Cover Speed Sleep Timer ON OFF Auto UV ...

Страница 8: ...lay Screen Display Screen Area Filter Replacement Indicator It will display when need to repalce filter meantime PM2 5 Value Display Air quality indicator will display different colors according to different PM2 5 value of room air Details as following figure 0 35 75 115 Good Moderate 500 Criteria Range µg m Air Quality Indicator Fan Speed Display Area Unhealthey Very Unhealthey Speed Sleep Timer ...

Страница 9: ... real time indoor air quality Note In the Auto mode short press the Speed button or Sleep button on the control panel to automatically exit Auto mode 2 4 UV Sterilization Short press the UV button on the control panel to turn on off the UV sterilization function when the main unit is turned on The UV button will be lit when the UV sterilization is turned on 2 5 Sleep Button Press the Sleep mode on...

Страница 10: ...2 5 value on display screen is very high and decreases extremely slow or the filter has an unusual smell please clean or replace the filter in time The shelf life of filter is 3000 hours When detecting filter needs to be replaced The filter replacement mark will be displayed on display screen of main unit The filter can not be washed The vacuum cleaner or brush can be used to clean PM2 5 and large...

Страница 11: ...place directly under the air container to avoid the condensation water to drop into the product Don not place directly in places of oil flammble gases or possible leakage places to avoid potential fire causes by those being absorbed into the product Do not place this device in an environment with heat fire moisture large dust and abnormal temperature to avoid power leakage to cause fire and electr...

Страница 12: ...ealth Don t put liquid or foreign substances to avoid any injury or damage 4 2 Power Cord and Power Plug a Power Plug Stop tousle and unplug the power cord immediately in the following cases to avoid electric shock fire or smoke Device stops running when power cord is moving Malfunction of any control button The power cord or power plug is abnormally hot There is burning smell Abnormal sound or vi...

Страница 13: ...e or release odor due to adsorption of contaminants The location of main unit may not be reasonable and cause device not easy to inhale air pollutants Check if detection port of sensor is blocked Change the position of the device Clean detection port Check whether the doors and windows are closed or whether there is a source of pollutants in room Check the filter is workable Remove and handle the ...

Страница 14: ...by the users enters into the device to cause abnormal operation c Trouble caused by unauthorized demolition repair or transformation of device d Trouble caused by accidental falling down in use or handling e Trouble caused by the failure to operate in accordance with the correct operations in user manual f The damage caused by unpredictable natural disasters such as fire earthquakes floods etc Fro...

Страница 15: ......

Страница 16: ......

Отзывы: