Warnings and precautions

 

 

Recovery probe 

 
 

 

 

Only one probe per stage is used per regulator. The probe is assigned to the INTAKE 
ventilator of the recuperator.  
 
The INTAKE fan will be activated based on this probe when the Avi35 is in recovery mode.  
 
If more than one recuperator is connected in series to the regulator, the manufacturer 
recommends to place the probe on the Avi35 recuperator which will be used during the 
departure of a flock, or the one which will work in the first place.  
 
The manufacturer recommends installing the probe at one end of the INTAKE fan leg support. 
The probe should be secured at a minimum distance of 8 cm from the motor. 
 

 

                 

         

Содержание AVI35

Страница 1: ...Installation and User Manual...

Страница 2: ...2...

Страница 3: ...take Ventilator 1 60Hz 240V 1 9A RPM 3255 CSA 172512 Exhaust Ventilator 1 60Hz 240V 1 9A RPM 3255 CSA 172512 Patent Pending USPTO 62 366 657 www distributionavi air com 114 Rang Roy 450 375 5539 Saint...

Страница 4: ...4 Table of content Electrician s note and diagram Page 5 Installation Guide Page 17 Warranty Page 21...

Страница 5: ...5 Electrician s Notes and Connection Diagram The manufacturer recommends that the electrical connection be performed by a qualified electrician...

Страница 6: ...is in recovery mode If more than one recuperator is connected in series to the regulator the manufacturer recommends to place the probe on the Avi35 recuperator which will be used during the departur...

Страница 7: ...board switch associated with the INTAKE fans is not set to automatic position The manufacturer recommends to check the reversal of rotation functions of the INTAKE fan at the first start of the Avi35...

Страница 8: ...t included providing a minimum of 10 gpm at 50 psi to provide sufficient water to the flushing system All regulators in the same building use the same centrifugal booster pump Each solenoid valve 240V...

Страница 9: ...ithout touching the electrical wire See diagram The INTAKE VENTILATORS must be connected in parallel to another variable relay of the regulator Drill the upper right corner of the inlet fan housing to...

Страница 10: ...10 INSTALLATION AND ELECTRICLAL DIAGRAM...

Страница 11: ...11 INSTALLATION AND ELECTRICLAL DIAGRAM...

Страница 12: ...12 Maximus AVI 28 CONNECTION DIAGRAM...

Страница 13: ...13 GENIUS MULTI ZONE AVI35 CONNECTION DIAGRAM With a pair of 3 poles interlock contactors and 1 NC...

Страница 14: ...14 EXHAUST FAN CONNECTION DIAGRAM...

Страница 15: ...15 INTAKE FAN CONNECTION DIAGRAM...

Страница 16: ...16 Installation Guide...

Страница 17: ...o recommends that a distance of at least 7 meters be maintained between the Avi35 recuperator and another standard building exhaust fan The aim is to prevent a return of stale and dusty air from other...

Страница 18: ...18 Installation diagram 1...

Страница 19: ...19 Installation Diagram 4...

Страница 20: ...ny modification and repair not authorized by the manufacturer on this product automatically void the warranty and relieves the manufacturer of any liability The manufacturer assumes only the aforement...

Отзывы: