22
ZM615 Indicator User Instructions
Operating Instructions
2.
Use the keypad on the ZM615 to enter up to seven digits for the ID. When you
have entered the ID, press the
ENTER
key and the following is displayed …
SETPT key (F3)
1.
Press and hold the
SELECT
key …
out1
is displayed followed by the current weight value for set point 1.
2.
Press
ENTER
to accept the displayed value or key in a new value and press
ENTER
to accept.
out2
is displayed followed by the current weight value for set point 2.
3.
Press
ENTER
to accept the displayed value or key in a new value and press
ENTER
to accept.
out3
is displayed followed by the current weight value for set point 3.
4.
Press
ENTER
to accept the displayed value or key in a new value and press
ENTER
to accept.
The indicator returns to the normal weighing mode
3.2.4 Performing Accumulation weighments
The accumulator application can be used to record totals of individual weighments.
Follow these steps:
1.
Press
ZERO
to zero the scale, if necessary …
0
is displayed.
2.
Place empty container on the scale and press
TARE
…
Net weight is displayed.
3.
Place item on the scale. Press
to add this weight to the accumulator
and to print the configured print format …
The
annunciator lights briefly and
Acc
is briefly displayed.
4.
Remove weight from the scale. Weight must return to inside the gross zero
band before another print and accumulation can be recorded.
kg
Gross
SETPT
CHAN
ID
ID: 7841
0
Accum Chan: 5
Net Total: 0 lb
Transactions: 0
Содержание ZM615
Страница 1: ...ZM615 Indicator User Instructions AWT35 501694 Issue AC...
Страница 4: ...4 ZM615 Indicator User Instructions...
Страница 31: ......