34
E1070 Service Manual
3
Using the Menus
Pushbutton tare
If you enable this item (
on
), you can use the
TARE
key to tare a
weight from the scale. If you disable (
oFF
) this item, you cannot
tare using the
TARE
key.
Enter tare
If you enable this item (
on
), you then choose between
rnd
(rounded tare) and
unrnd
(unrounded tare). When enabled you
can enter a known tare weight by keying in a weight and pressing
the
TARE
key. If set to
rnd
the entered tare value is rounded to
the division size. If set to
unrnd
the entered tare value is not
rounded to the division size.
Automatic Tare
If you enable this item (
on
), the indicator automatically tares off
any weight on the scale when the weight is both above a
configurable threshold and stable.
EnAbLE
Enable or Disable the auto-tare feature. Default is
oFF
.
Lo
Numeric entry, as a percentage of capacity, to set the
low threshold limit.
Hi
Numeric entry, as a percentage of capacity, to set the
High threshold limit.
The Lo and Hi two settings are the lower and upper thresholds that
define the auto-tare window.
When the net weight on the scale is above the lower threshold and
below the upper threshold and the delay has expired and the
weight is stable, an automatic tare is triggered.
Setting the lower or upper limit to zero disables this automatic tare
feature. The indicator can be set up to clear the tare when the
gross weight returns to with the Gross Zero Band.
A-Prnt
If enabled, a print will occur whenever an automatic tare
is done. The “formats-to-print” setting for the current
application determines what print formats are set (the
same formats will be printed when the print key is
pressed).
dELAY
Entered in seconds, this defines the amount of time
after the weight falls into the auto-tare window until an
auto-tare is done.
Follow these steps to set the tare item:
1.
With
AZt
displayed, press the
UNITS
key…
tArE
is displayed.
2.
Press the
key…
CLEAr
is displayed.
3.
Press the
key…
on
or
oFF
is displayed. Use this to enable or disable the Clear tare item.
The print formats are completed before the automatic tare is done. Therefore, if net
weight is printed in the print format(s) it will not be zero.
Содержание E1070
Страница 1: ...Model E1070 Indicator Service Manual NORTH AMERICA AWT35 500106 Issue AF March 2010 ...
Страница 6: ...6 E1070 Service Manual ...
Страница 51: ...E1070 Service Manual 51 3 4 Service Menu Table 3 1 Printalbe Characters Chart ...
Страница 146: ...146 E1070 Service Manual 8 Network Connections ...
Страница 149: ...E1070 Service Manual 149 10 Complete Menu Structures 10 1 Complete Supervisor and User Menus Supervisor Menu User Menu ...
Страница 150: ...150 E1070 Service Manual 10 2 Complete Service Menu ...
Страница 153: ...E1070 Service Manual 153 11 3 Wall Mount Application ...
Страница 154: ...154 E1070 Service Manual 11 4 System Block Diagram ...
Страница 155: ...E1070 Service Manual 155 11 5 Keypad Schematic and Power Supply Bd P N 60071 0016 ...
Страница 158: ...158 E1070 Service Manual 11 8 I O External Calbe Identification Pin outs ...
Страница 162: ...162 E1070 Service Manual ...
Страница 163: ......