SM-1000.56 

Pneumatic Cylinder 

14” Bore X 22” Stroke 

Part No. R434001268 

(Formerly P -193419-00003) 

 

Service Information

 

 INSTALLATION 
 

  Before installing this cylinder, all air lines in the 
system should be blown clean to remove any 
moisture or loose material. Also, the area in which 
the cylinder is to be mounted should be free of any 
foreign objects, which may damage the cylinder 
barrel. To further ensure a long, trouble-free 
service, an efficient air filter should be installed in 
the system’s supply line.  
 
  Start the installation by removing one cotter pin 
and clevis pin from the clevis on the cap end of the 
cylinder. Set the cylinder into the mounting position 
with the cap clevis mating with the mounting eye. 
Reinstall the clevis pin through the clevis lugs, and 
the cotter pin into the clevis pin. Spread the ends of 
each cotter pin so that they will not fall out. You 
can now connect the piston rod end to the 
mounting bracket, noting proper alignment to 
eliminate any binding.  
 

 
 
  Remove the thread protectors from each pipe 
port in the head and cap; connect air lines from the 
directional control valve. Use pipe dope on the air 
line fittings, not any kind of tape. Be sure no foreign 
matter enters the ports or air lines during the time 
they are open. 
 
  If the cylinder is to be painted, be sure that the 
piston rod is covered, the ports are closed, and the 
clevis pin is covered where it rides in the clevis. 
 
 The supply air and atmospheric (ambient) 
condition must be maintained within a temperature 
range of  –40°F to +225°F. 