WEB08S-TA Web Client Attendance RFID reader
12
3.1.8 $ver
It is the firmware revision. Currently it is 1.5.
3.1.9 $contact
It is used with $cmd=SW to indicate the state of the contact switch. If the switch is opened,
$contact=OPEN. If the switch is closed, $contact=CLOSE.
3.1.10 $recno
Hold the reference number of the record in decimal format. The server must response
this parameter in order to acknowledge the record and confirm the deletion of that record.
3.1.11 $rdate and $rtime
Hold the date and time of the stored record. The format of date is YYYY-MM-DD, e.g.
2007/01/23 means 23
rd
Jan 2007. The format of time is HH:MM:SS where HH is hour,
MM is minute and SS is second.
3.1.12 $sid
This is the value set by the SID response.
3.1.13 $deviceid
This is the unique id of the reader.