background image

WEB08S-TA Web Client Attendance RFID reader 

 

WEB08S-TA TCP/IP Ethernet HTTP Web Client RFID Reader 

for Attendance 

 

WEB08S-TA is a TCP/IP Ethernet based RFID reader for 

125KHz RFID cards. Battery backed real-time clock and 

memory is included. 

 

It is implemented as a HTTP web client. Various page 

extension is selectable, like .php, .asp, .cfm, .pl, .htm, .html 

and .aspx. So various HTTP server systems (e.g. IIS and ASP 

from Microsoft; Apache with PHP enabled and mySQL 

database server from Unix/Linux), a complete and powerful 

time attendance system can easily be implemented. 

 

Since the real-time clock is battery backed, even the power is 

lost the clock is still running properly. 

 

When cards are presented, the transaction information is 

stored inside the memory of the reader. Whenever there is network connection and the server 

is running, those records will be sent to the server. Upon confirmation by the server, the 

records will be deleted accordingly. 

 

The memory is capable to store up to 1000 records. The 

memory is retained even power is lost. Whenever a card is 

presented to the reader, the record is stored with a short beep 

sound for the acknowledgement of the record stored. When 

the memory is used up, a long beep sound will be made. The 

oldest record will be deleted in order to store the newest 

record. 

 

 

 

Содержание WEB08S-TA

Страница 1: ...WEB08S TA USER MANUAL TCP IP Ethernet HTTP WEB CLIENT RFID READER For Attendance 21st Nov 2012 AVEA International Company Limited http avea cc...

Страница 2: ...k 6 2 1 2 Power from Cat 5 e Ethernet cable 6 2 2 EXTERNAL RELAY CONTROL 7 2 3 CONTACT SWITCH 8 2 4 SLAVE READER 8 2 5 MECHANICAL DIMENSIONS 9 2 6 BATTERY 9 3 SOFTWARE 10 3 1 REQUESTS TO HTTP SERVER 1...

Страница 3: ...14 3 2 6 ROOT xxxxxxxx 14 3 2 7 EXT x 14 3 2 8 DHCP x 15 3 2 9 IP xxx xxx xxx xxx 15 3 2 10 GW xxx xxx xxx xxx 15 3 2 11 NM xxx xxx xxx xxx 15 3 2 12 WS xxx xxx xxx xxx 16 3 2 13 PT xxxxx 16 3 2 14 RL...

Страница 4: ...e implemented Since the real time clock is battery backed even the power is lost the clock is still running properly When cards are presented the transaction information is stored inside the memory of...

Страница 5: ...reader itself 192 168 1 234 GW Gateway IP address 192 168 1 1 NM Netmask 255 255 255 0 WS HTTP server IP address 192 168 1 1 PT HTTP server port number 80 EXT Page extension php 1 2 Reset WEB08S TA to...

Страница 6: ...style ad hoc subnet 192 168 1 0 netmask 255 255 255 0 default gateway option routers 192 168 1 1 default gateway option subnet mask 255 255 255 0 netmask option www server 192 168 1 123 it must setup...

Страница 7: ...es 9 to 12V DC 500mA for normal operation There are two ways to supply the power to the reader 2 1 1 Terminal Block Apply the power to the terminal block with positive terminal to VIN and negative ter...

Страница 8: ...common it will connects to either NO or NC but not both NO normal open it is open circuit normally The maximum switching voltage of the relay is 120VAC or 60VDC and the maximum switching current is 2...

Страница 9: ...ader MODEL NO KS232S to work together and the host software can identify the actions is come from the WEB08S TA or the slave reader by check the variable type The following is the connection diagram a...

Страница 10: ...n to power supply for WEB08S TA and the slave reader 2 5 Mechanical Dimensions Height 97mm Width 57mm Depth 24mm 2 6 Battery A CR1220 lithium cell battery is required for the normal operation of the r...

Страница 11: ...a GET request to access a fixed web page of the HTTP server avea php located on the root of the website The file extension is user selectable e g avea asp avea cfm avea pl avea htm and avea html But i...

Страница 12: ...umber is stored in code III cmd HB it is sent when the programmed heartbeat rate is reach The default heartbeat rate is 300 seconds IV cmd SW it is sent once when contact switch is just shorted or ope...

Страница 13: ...reference number of the record in decimal format The server must response this parameter in order to acknowledge the record and confirm the deletion of that record 3 1 11 rdate and rtime Hold the dat...

Страница 14: ...sponses are supported 3 2 1 HB xxxx Set the heartbeat rate of the reader in seconds It is a fixed length format in decimal value Example HB 0300 set the reader send a heartbeat request to the HTTP ser...

Страница 15: ...d LED off 3 2 5 DENY Set the reader to a deny access state i e to make sure the relay is in NO state 3 2 6 ROOT xxxxxxxx This will change the root page to be access by the reader It is a fixed length...

Страница 16: ...server IP 3 2 9 IP xxx xxx xxx xxx This is a fixed length command and values are in decimal It will change the IP address of the reader Example IP 192 168 001 234 3 2 10 GW xxx xxx xxx xxx This is a...

Страница 17: ...2 14 RLY x This is a fixed length command and values are in decimal If RLY 1 the relay will be turned on If RLY 0 the relay will be turned off The state of relay will be affected by the subsequence co...

Страница 18: ...o correct format mycard 359452 replaced by your card number rtime date time access the date and time of the reader remote_open 1 echo AVEA starting flag switch cmd case PU power up echo CK st set cloc...

Страница 19: ...ID reader 18 case HB heartbeat echo CK st set clock break case PG being pinged if _GET contact CLOSE echo GRNT 01 grant access break case SW being pinged if remote_open 1 echo GRNT 01 grant access bre...

Отзывы: