Safety

 25

Electrical Safety

DC P

OWER

Warning   

Voltages over 60 V DC can be present in this equipment. This

equipment is intended to be accessed, installed and maintained by qualified and 
trained service personnel only.

Warning   

Avoid electrical overload. To avoid electrical hazard, do not make 

connections to terminals outside the specified voltage range of the shelf in use.

Warning   

Although there are fuses in the power entry circuit of the shelf, power 

lines must be protected on the rack level with 20A breakers.

Warning   

Before removing a power entry module, make sure that the power 

segments of other power entry modules are fully functional.

Warning   

Before performing any of the following procedures, ensure that power 

is disconnected from the DC circuit. To ensure that all power is switched off, 
locate the circuit breaker on the panel board that services the DC circuit, switch 
the circuit breaker to the off position, and tape the switch handle of the circuit 
breaker in the off position.

Warning   

Care must be given to connecting units to the supply circuit so that 

wiring is not overloaded.

Caution   

To maintain proper airflow, do not leave a power entry module slot open.

Note   

The Shelf can be powered using a regular telecommunication power supply 

of -48 VDC / -60 VDC with a voltage return. The specified voltage range is from 
-40.5 VDC to -72 VDC.

ESD P

ROCEDURES

 

To prevent damage to 

Avaya

 element boards by random electrostatic

 

discharge (ESD), the use of wrist straps is highly recommended.

Содержание Scopia Elite 5200 Series

Страница 1: ...Platform Guide for Avaya Scopia Elite 5200 Series MCU Version 8 3 For Solution 8 3 October 2015...

Страница 2: ...U DO NOT WISH TO ACCEPT THESE TERMS OF USE YOU MUST NOT ACCESS OR USE THE HOSTED SERVICE OR AUTHORIZE ANYONE TO ACCESS OR USE THE HOSTED SERVICE YOUR USE OF THE HOSTED SERVICE SHALL BE LIMITED BY THE...

Страница 3: ...nux OS source code for those products that have distributed Linux OS source code and identifying the copyright holders of the Third Party Components and the Third Party Terms that apply is available i...

Страница 4: ...el Features 4 Shelf Manager 5 Shelf Manager Main Features 5 Shelf Manager Panel Features 6 2 Rack Mounting the SCOPIA Elite MCU What to Consider Before Installing the Brackets 7 Mount Kit Description...

Страница 5: ...ial Port Terminal Cable 17 RJ 45 8 Pin IP Network Port 18 100 Mbps Ethernet 18 1 Gbps Ethernet 19 4 Safety Installation Safety 21 Electrical Safety 21 Grounding 22 Power Supply 23 DC Power 25 ESD Proc...

Страница 6: ...tform documentation set is available on the Avaya Utilities and Documentation CD ROM supplied with the product and includes manuals in PDF format Note You require Adobe Acrobat Reader version 6 0 or l...

Страница 7: ...viPlatform Guide for SCOPIA Elite MCU 5200 Series MCU Release 7 1...

Страница 8: ...ents The SCOPIA Elite 5200 Series MCU chassis Two SCOPIA Elite Media Blades A SCOPIA Elite 5200 Series MCU Shelf Manager We describe each component in these sections SCOPIA Elite 5200 Series MCU Chass...

Страница 9: ...e 5200 Series MCU Chassis The upper MCU functions as the master blade providing the single management interface and controlling both blades in the chassis The LAN connection is via the upper blade The...

Страница 10: ...oes not affect the operation of other FRUs Grounding and electrostatic discharge The chassis includes an external GND 4mm stud as per the TUV requirement The chassis includes 4mm banana jacks for a 4...

Страница 11: ...r Panel SCOPIA ELITE MEDIA BLADE PANEL FEATURES Figure 1 3 SCOPIA Elite Media Blade Front Panel STATUS STATUS RESET HOT SWAP RESET HOT SWAP PWR ALARM STATUS FAN ALARM R FAN ALARM L MEDIA BLADE MEDIA B...

Страница 12: ...occurred and that the Media Blade requires resetting 2 Serial connector A DB 9 connector that allows you to connect a PC terminal for local configuration maintenance and debugging 3 100 1000 BASE T E...

Страница 13: ...eration FAN ALARM L LED Lights red if the tacho speed in one or more fans in the left fan tray falls below 900 rpm FAN ALARM R LED Lights red if the tacho speed in one or more fans in the right fan tr...

Страница 14: ...s Note The MCU chassis is heavy Do not attempt to lift it by yourself Have someone assist you This document covers both how to install the brackets and how to rack mount the MCU chassis What to Consid...

Страница 15: ...d ensure that this space is not blocked to prevent air from short circulating front to rear Allow sufficient clearance around the rack for maintenance If the rack is mobile you can push it back near a...

Страница 16: ...ting Kit Table 2 1 Rack Mount Parts HOW TO INSTALL THE BRACKETS Rack Attachment Location on page 10 Identifying The Bracket Parts on page 10 Item Quantity Part Description 1 1 Right Mounting Bracket 2...

Страница 17: ...You secure the brackets through these holes Figure 2 2 Mounting Strips on the Rack Posts IDENTIFYING THE BRACKET PARTS The inner side of each bracket has a turned ledge at the bottom that forms a she...

Страница 18: ...ack Mounting Brackets ADJUSTING THE BRACKET LENGTH You must adjust the length of each bracket to correspond with the depth of your rack Each bracket has two pieces that slide one inside the other with...

Страница 19: ...nch to release the bracket s Allen screw 2 For each bracket slide the two bracket parts until the round hole meets the elliptic hole corresponding to the depth of the rack 3 Insert the Allen screw whe...

Страница 20: ...nd make sure that they are all at the same height 2 Locate the two mounting holes at each side of each bracket as shown in Identifying The Bracket Parts on page 10 Make sure to first identify which br...

Страница 21: ...e it in an area that exceeds the maximum recommended ambient temperature of 113 F 45 C CHASSIS LIFTING GUIDELINES A fully configured SCOPIA Elite MCU chassis weighs approximately 44lbs 20kg The chassi...

Страница 22: ...a shelf you can now mount the SCOPIA Elite MCU chassis Before mounting the chassis read the Safety Guidelines section on page 14 and the Chassis Lifting Guidelines section on page 14 To rack mount th...

Страница 23: ...the rack posts ATTACHING THE SYSTEM GROUND Before connecting power or turning ON power to the MCU it strongly recommend that you provide an adequate chassis ground earth connection for the chassis You...

Страница 24: ...IONS AND PIN OUTS 9 Pin Serial Port Terminal Cable on page 17 RJ 45 8 Pin IP Network Port on page 18 9 PIN SERIAL PORT TERMINAL CABLE Table 3 1 describes the pin to pin configuration of the RS 232 ter...

Страница 25: ...NETWORK PORT 100 Mbps Ethernet on page 18 1 Gbps Ethernet on page 19 100 MBPS ETHERNET Table 3 2 describes the pin out configuration of the 100 Mbps RJ 45 Ethernet connector Table 3 2 Pin out Configur...

Страница 26: ...19 RJ 45 8 Pin IP Network Port Connector 1 GBPS ETHERNET Table 3 3 describes the pin out configuration of the 1 Gbps RJ 45 Ethernet connector Pin Function I O 1 TXD Output 2 TXD Output 3 RXD Input 4...

Страница 27: ...ernet Connector Pin Name Function I O 1 BI_DA Bi directional pair A I O 2 BI_DA Bi directional pair A I O 3 BI_DB Bi directional pair B I O 4 BI_DC Bi directional pair C I O 5 BI_DC Bi directional pai...

Страница 28: ...ire hazard do not operate this product with any removed enclosure covers or panels To avoid the risk of electric shock do not operate in wet damp or condensing conditions To avoid electrical hazards h...

Страница 29: ...age 25 GROUNDING This SCOPIA Elite 5200 Series MCU platform must be grounded Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is a...

Страница 30: ...uctor Plug the unit into a wall socket outlet which is connected to the protective earth contact Do not use socket outlets which are not connected to a protective earth contact Varoitus Laite on liite...

Страница 31: ...t all power and external cables before installing or removing a chassis Work with at least one other person when potentially hazardous conditions exist Disconnect the power from a circuit Do not perfo...

Страница 32: ...Warning Before performing any of the following procedures ensure that power is disconnected from the DC circuit To ensure that all power is switched off locate the circuit breaker on the panel board t...

Страница 33: ...processor heatsinks When removing the fan tray keep your hands and fingers away from the spinning fan blades Let the fan blades completely stop before you remove the fan tray Warning There is a danger...

Страница 34: ...on page 28 SAFETY COMPLIANCE This section lists the safety standards supported by the SCOPIA Elite 5200 Series MCU platform IEC 60950 1 2nd Edition UL 60950 1 2nd Edition CAN CSA C22 2 No 60950 1 2nd...

Страница 35: ...perated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful inter...

Отзывы: