Maintenance-Object Repair Procedures
555-233-143
8-172
Issue 1 May 2002
b. Error Type 129: the far-end switch changed its ISDN service state to either
out-of-service or maintenance. This may be a temporary condition
because the far end is testing that trunk or a hardware problem with the
trunk. Outgoing calls may not be allowed over that trunk.
1. Investigate the trunk’s status (status trunk grp#/mbr#).
c. Error Type 130: the circuit pack has been removed or has been insane for
more than 11 minutes.
1. Reinsert or replace the circuit pack to clear the error.
d. Error Type 257: SETUP received for a B channel that is in an invalid
service state. Service states may be incompatible at the two ends of the
trunk. A normal call was received while the B channel was MTC/FE,
MTC/NE, OOS/FE, or OOS/NE or a test call was received while the
B channel was OOS/FE or OOS/NE.
e. Error Type 513: RELease COMplete message received with cause value
82 (nonexistent channel). The B channel may not be administered at the
far end. The trunk has been placed in the OOS/FE state.
f. Error Type 769: inconsistent SERVice or SERVice ACKnowledge
message. Possible causes:
■
SERVice or SERVice ACKnowledge message received containing a
change status that is more available than the previously-transmitted
SERVice message.
■
Unsolicited SERVice ACKnowledge message received containing a
change status that does not match the current B-channel state.
ISDN-PRI service-state negotiation rules have been violated and may
indicate that a pending service-state audit is failing. The system:
■
cancels the maintenance timer
■
increments the Service State Audit counter
■
attempts a Service State Audit
When running the short test sequence, pay close attention to the results of
the Service State Audit test (#256).
g. Error Type 1793: TN230x circuit pack has failed. The maintenance system
■
places the trunk in the OOS/NE state
■
sends a SERvice message to the far end (if possible) containing a
change status of OOS for the B channel
■
returns the trunk to service when the ATM trunk circuit pack reports
the failure cleared
h. Error Type 3073: Service State Audit attempt failed. See
. Calls can be received but not placed until the test
passes and the trunk state returns to In-Service.
1. Check the trunk’s status (status trunk grp#/mbr#).
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...