Alarms, Errors, and Troubleshooting
555-233-143
4-12
Issue 1 May 2002
Figure 4-2.
Determining the Cause of a Server Interchange
Use the SYSTEM error table following this
chart to determine which SPE component
is implicated.
This indicates a serious processor/memory
bus problem. Busyout or, preferably, lock
the standby SPE to prevent an
interchange, and escalate the problem.
Consult MO documentation for PKT-INT.
Is there a Major alarm against
the standby SW-CTL?
no
no
no
no
no
no
no
no
Consult MO documentation for TAPE.
Consult the MO documentation for the
indicated component.
yes
yes
yes
yes
Replace the standby
MSSNET circuit pack.
yes
yes
Consult CARR-POW in
Chapter 9.
yes
yes
If handshake is down (check status spe),
replace the alarmed standby circuit pack
If handshake is up, execute a
test long clear of the alarmed
component and consult documentation
for that MO in Chapter 9.
Proceed to the next flowchart, Testing
the Standby SPE
Is there a TAPE error 3585 with aux code 408?
Is there a PKT-INT error 100?
Is there an error 150 against any SPE component?
Is there a SYSTEM error 6002, 6003,
6102, or 6103?
Enter display errors and look for unalarmed
errors for SPE components, CARR-POW
and SYSTEM. Is there a SYSTEM
error 6001 or 6101.
Enter display alarms for categories SPE
and environ. Are there any major
alarms against CARR-POW?
Are there major alarms against other
SPE components?
All relevant alarms must be timestamped at or near the time of interchange.
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...