Maintenance-Object Repair Procedures
555-233-143
8-94
Issue 1 May 2002
Table 8-37.
Test #47 Loop Around and Conference Test
Error
Code
Test
Result
Description / Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
7
ABORT
The port was seized by a user for a valid call.
1. Enter display port UUCSSpp to determine the station’s extension. Enter
status station extension to determine the service state of the port. If the
port is active, it will be unavailable for certain tests. Wait until the port is
idle before retesting.
2. If the port is idle, retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test were not available. The port may be
busy with a valid call. (This could be a Music-on-Hold port.)
1. Enter display port UUCSSpp to determine the station’s extension. Enter
status station extension to determine the service state of the port. If the
port is active, it will be unavailable for certain tests. Wait until the port is
idle before retesting.
2. If the port is idle, retry the command at 1-minute intervals up to 5 times.
1002
ABORT
The system could not allocate time slots for the test. The system may be under
heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at 1-minute intervals up to 5 times.
1003
ABORT
The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present or some Tone Detectors
may be out-of-service.
1. Resolve TTR-LEV errors.
2. Resolve TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals up to 5 times.
1004
ABORT
The port has been seized for a valid call during the conference or noise test.
1. If the circuit pack is a TN742 of Vintage 10 or less, this test is not valid.
Otherwise, proceed with step 2.
2. When the port is available for testing, retry the command at 1-minute
intervals up to 5 times.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...