PNC Cabling — Fiber Hardware
Issue 1 May 2002
2-3
555-233-143
PNC Cabling
—
Fiber Hardware
The term “fiber” is used to refer to all the hardware needed for the three basic
types of connections used to form multi-PN systems. Fiber administration
specifies the endpoints to be connected, optional DS1 CONV locations, and
parameters for DS1 facility line encoding and equalization. The three connection
types are:
1. EI-to-EI or EI-to-SNI intercabinet hardware
2. EI-to-SNI or EI-to-EI intracabinet hardware
3. EI-DS1CONV or SNI-DS1CONV hardware
EI-to-EI or EI-to-SNI Intercabinet Fiber-Optic
Cables
EI-to-EI or EI-to-SNI intercabinet connections are implemented by installing a
lightwave transceiver on the I/O connector plate for each of the administered fiber
endpoints. Each lightwave transceiver has a receive and a transmit connector for
either a 62.5-micron or 50-micron fiber connection. Standard fibers are available
in various lengths up to 150 feet (46 m) for single-mode fiber and up to 200 feet
(61 m) for multimode fiber. These fibers are used to connect lightwave
transceivers to each other when they are close enough together, or to optical
cross-connect facilities for greater distances.
The lightwave transceivers are powered from I/O connector plate leads attached
to TN570 Expansion Interface circuit pack or a TN573 SNI circuit pack. The
transceivers include loop-around capabilities to support fiber fault isolation. Either
of two different 9823-type multimode transceivers may be used, depending upon
the length of the fiber (table below), or the 300A single mode fiber transceiver.
The transceivers at each end of a given fiber should match.
illustrates the interconnection of fiber-optic hardware.
Part Number
Maximum Fiber Length
Fiber Mode
9823A
4900 feet (1494 m)
multimode
9823B
25,000 feet (7620 m)
multimode
300A
22 miles (35.4 km)
single mode
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...