Table 8-603.
Test #595 LAN Receive Parity Error Counter Test
Error
Code
Test
Result
Description / Recommendation
2000
ABORT
Response to the test was not received from the circuit pack within the allowable
time period.
1. If the test aborts repeatedly up to 5 times, reset the circuit pack via the
busyout board UUCSS and reset board UUCSS commands.
2. If the test aborts again, replace the circuit pack.
2100
ABORT
Could not allocate the necessary system resources to run this test.
2012
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
1–10
FAIL
The circuit pack is still detecting errors of this type. The error code indicates
the value of the on-board error counter.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to fail, verify the validity of the Packet bus. Run the
Packet bus maintenance test with the test pkt P long command. If any
Packet bus tests fail, see
‘‘PKT-BUS (Packet Bus)’’ on page 8-1230
recommended repair procedures.
3. If the Packet bus test passes, check the validity of the circuit pack.
Execute a test that involves data transmission onto the Packet bus. For
example, the test port UUCSSpp command may use the connectivity
tests of the BRI-PORT MO. If the test fails, refer to the repair procedures;
otherwise, proceed to the next step.
4. Other circuit packs on the Packet bus may be causing of the parity error.
Use the display errors command to check the Error Log for alarmed other
circuit packs. Resolve any alarms for other circuit packs as well. Rerun
the LAN Receive Parity Error Counter test (#595).
PASS
No errors detected.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...