![Avaya S8700 Series Скачать руководство пользователя страница 2144](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_30271022144.webp)
Maintenance-Object Repair Procedures
555-233-143
8-1422
Issue 1 May 2002
SNC-LINK (Switch Node Clock Link)
The SNC-LINK MO reports errors in communications between the active Switch
Node Clock and Switch Node Interfaces over the serial channel (aux data 1) and
the TPN link (aux data 2). SNC-LINK errors are described on the following pages.
For a complete description of SNCs and SNIs, including circuit pack replacement
instructions, see MOs
Error Log Entries and Test to Clear Values
MO’s Name (in
Alarm Log)
Alarm
Level
Initial SAT Command to
Run
1
1.
UU is the universal cabinet number (1–64 for ATM PNC, 1–44 for CSS PNC). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot where the circuit pack resides (10 or
12).
Full Name of MO
SNC-LINK
MINOR
test board UUCSS s
SNC Link
Table 8-573.
SNC-LINK Hardware Error Log Entries
Error
Type
Aux
Data
SNI
Slot
1
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
2
0
Any
Any
Any
test board UUCSS r 1
1
1 (a)
2
Failure audit (#777)
MINOR
OFF
test board UUCSS r 1
1
2 (b)
2
Failure audit (#777)
MINOR
OFF
test board UUCSS r 1
257
1 (a)
3
Failure audit (#777)
MINOR
OFF
test board UUCSS r 1
257
2 (b)
3
Failure audit (#777)
MINOR
OFF
test board UUCSS r 1
513
1 (a)
4
Failure audit (#777)
MINOR
OFF
test board UUCSS r 1
513
2 (b)
4
Failure audit (#777)
MINOR
OFF
test board UUCSS r 1
769
1 (a)
5
Failure audit (#777)
MINOR
OFF
test board UUCSS r 1
769
2 (b)
5
Failure audit (#777)
MINOR
OFF
test board UUCSS r 1
1025
1 (a)
6
Failure audit (#777)
MINOR
OFF
test board UUCSS r 1
1025
2 (b)
6
Failure audit (#777)
MINOR
OFF
test board UUCSS r 1
1281
1 (a)
7
Failure audit (#777)
MINOR
OFF
test board UUCSS r 1
1281
2 (b)
7
Failure audit (#777)
MINOR
OFF
test board UUCSS r 1
1537
1 (a)
8
Failure audit (#777)
MINOR
OFF
test board UUCSS r 1
1537
2 (b)
8
Failure audit (#777)
MINOR
OFF
test board UUCSS r 1
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...