PKT-BUS (Packet Bus)
Issue 1 May 2002
8-1237
555-233-143
Packet Circuit Pack Audit Test (#573)
This test determines whether Packet circuit packs have reported Packet
Bus-related in-line errors within the last minute. If so, the failure code indicates
whether one or more than one circuit pack has reported such failures.
If the test has failed within the last 5 minutes, there is a 15 second delay before
the result is returned. This prevents a repeated sequence of this test from always
reporting the same result. If the test passes and a FAIL has not occurred within
the last five minutes, a PASS is returned immediately.
PASS
No faults have been detected on the packet bus by the Maintenance/Test
circuit pack. This is an indication that the packet bus is operating correctly.
Table 8-506.
Test #573 Packet Circuit Pack Audit Test
Error
Code
Test
Result
Description / Recommendation
2500
ABORT
An internal operation failed; the test could not be repeated.
1. Re-enter the command at 1-minute intervals up to 5 times.
1
FAIL
One Packet circuit pack has reported packet bus-related in-line errors within
the last minute.
2
FAIL
More than one Packet circuit pack has reported packet bus-related in-line
errors within the last minute.
PASS
No Packet circuit packs have reported packet bus-related in-line errors within
the last minute. This indicates that the packet bus is healthy, or that a packet
bus fault is transient or is being caused by a faulty Packet circuit pack. If this
test passes, but there are other signs of a packet bus failure (for example,
logged errors or alarms, or other test failures), see the
section in
Chapter 4, ‘‘Alarms, Errors, and
Table 8-505.
Test #572 Maintenance/Test Circuit Pack Query Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...