HYB-LINE (Hybrid Line)
Issue 1 May 2002
8-921
555-233-143
Hybrid Line Audits Test (#61)
This is a series of three tests that are classified as audits. These audits will abort
if attempted on an out-of-service station. The tests are as follows:
■
Switchhook Audit — This updates the media server’s records according to
the circuit packs’ records.
■
Bad Scan Inquiry — An up-link message is sent containing a count
generated due to certain events relating to the data link’s conditions. This
indicates data-transmission problems between the Hybrid circuit pack and
the voice terminal.
■
EPF Inquiry — An up-link status message of the Electronic Power Feed is
sent. Possible conditions are: EPF-on-ok, EPF-off, EPF-no-load, and
EPF-on-overcurrent.
Table 8-356.
Test #61 Hybrid Line Audits Test
Error
Code
Test
Result
Description / Recommendation
ABORT
Internal system error
1
ABORT
The test was aborted due to an internal system error during the switchhook
audit.
2
ABORT
Internal system error occurred during bad scan inquiry audit.
1. Make sure that the station is not in an out of service state.
2. Retry the command at 1-minute intervals up to 5 times.
3
ABORT
This port may have been busied out by system technician.
1. Look in the Error Log for Error Type 18 (port busied out) for this port. If this
Error Type is present, release the port via the release station extension
command and run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use the display port UUCSSpp to determine the station extension
number of the port. Use the status station command to determine the
service state of the port. If the port is in use, wait until it is idle before
testing.
2. If the port status is idle, then retry the command at 1-minute intervals up to
5 times.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...