Alarms, Errors, and Troubleshooting
555-233-143
4-90
Issue 1 May 2002
Overview of Fault Correction Procedures
This section gives an overview of the procedures used to isolate the cause and to
correct packet bus faults. Details are presented in following sections.
1. Procedure 1 attempts to determine whether a circuit pack that interfaces to
the packet bus is the cause of the packet bus problem. This involves
examination of the error and alarm logs followed by the usual repair
actions.
2. If the packet bus problem persists, remove port circuit packs (those in
purple slots) to look for circuit packs that have failed and/or damaged the
packet bus pins.
3. If the packet bus problem persists, perform the same procedure for control
complex circuit packs.
4. If the problem persists, or if the packet-bus faults are known to have open
leads, replace bus terminators and cables. If this does not resolve the
problem, reconfigure the carrier connectivity of the EPN to attempt to
isolate a faulty carrier.
Maintenance/Test Circuit Pack (TN771D)
The TN771D Maintenance/Test circuit pack provides the following functions:
■
Analog Trunk (ATMS) testing
■
Digital Port Loopback testing
■
ISDN-PRI Trunk testing
■
Packet Bus testing
■
Packet Bus reconfiguration (critical-reliability systems only)
Critical-reliability systems have a TN771D in each EPN. A TN771D is optional in
EPNs of other configurations. The ISDN-PRI trunk testing functions are
discussed in
‘‘ISDN-PLK (ISDN-PRI Signaling Link Port)’’ on page 8-965
.
The digital port testing functions are discussed in the following sections in
8, ‘‘Maintenance-Object Repair Procedures’’
■
‘‘DIG-LINE (Digital Line)’’ on page 8-538
■
‘‘DAT-LINE (Data Line Port)’’ on page 8-489
■
‘‘PDMODULE (Processor Data Module) TDMODULE (Trunk Data
Module)’’ on page 8-1196
■
‘‘TDMODULE (Trunk Data Module)’’ on page 8-1619
■
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...