EXP-INTF (Expansion Interface Circuit Pack)
Issue 1 May 2002
8-811
555-233-143
Table 8-310.
Test #589 Expansion Interface Packet Interface Test
Error
Code
Test
Result
Description / Recommendation
1033
ABORT
The test cannot run because the EI circuit pack does not have a fiber link
administered to it and there is not sufficient data to run the test or because EI
circuit packs on other port networks needed for this test are out of service.
1. Execute the list fiber-link command and determine whether the EI circuit
pack under test is an endpoint of one of the administered fiber links. If so,
then proceed to step 2. If not, then this is considered to be a spare board,
and the test should not be attempted on this EI circuit pack.
2. Follow procedures for applicable configuration:
DIRECT CONNECT
1. Issue the list config command for the cabinet and carrier where the
neighbor EI circuit pack resides. If the results reveal that the board is not
recognized by software, the board is out of service because of this
condition. Perform the following steps:
a. If this test is being executed on an EI circuit pack located in the
PN, enter display errors and resolve any EXP-PN errors for the
port network where the neighbor EI circuit pack resides.
Re-execute this test.
b. If this test continues to abort with this abort code reset the DS1
CONV circuit pack (if so equipped) or the neighbor EI circuit
pack. This will not be destructive since the circuit pack cannot be
serving as the Expansion Archangel if it is not in service.
2. Run Test #237 and check for EXP-INTF circuit pack Error Type 1281 in the
Error Log. If Error Type 1281 is present and/or Test #237 does not pass,
see repair procedures for Test #237, in
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...