![Avaya S8700 Series Скачать руководство пользователя страница 151](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_3027102151.webp)
Troubleshooting ISDN-PRI Test Calls
Issue 1 May 2002
4-77
555-233-143
Troubleshooting ISDN-PRI Test Calls
An ISDN-PRI test call is placed across an ISDN-PRI user-network interface to a
previously designated number in order to test ISDN capabilities of the switch, the
trunk and the far end. An ISDN-PRI test call is also a maintenance procedure
concerned with the identification and verification ISDN-PRI user-network interface
problems. The ISDN-PRI test call can access ISDN-PRI trunks only.
An ISDN-PRI test call can be placed only if the circuit translates to an ISDN-PRI
trunk. An ISDN-PRI test call can be originated through either the synchronous or
the asynchronous method. Each method is described in the following sections.
NOTE:
Before attempting to make an ISDN-PRI test call to the public network (the
far end), make sure that test call service is provisioned by the network. The
user must subscribe to Test Type 108 service and have the correct far-end
test call number administered on the Trunk Group form for the call to be
allowed.
Synchronous Method
One command is used in this method to start, stop, and query an ISDN-PRI test
call. In the synchronous method, an outgoing ISDN-PRI test call may be part of
one of the following long test sequences entered at the terminal:
■
test trunk grp/mbr long [repeat#]
■
test port UUCSSpp long [repeat#]
■
test board UUCSS long [repeat#]
The long qualifier must be entered in the above commands in order for the ISDN
test call to run. The repeat number (#) can be any number from 1 through 99
(default = 1).
The following information is displayed in response to the above commands:
■
Port: The port address (UUCSSpp) is the port network’s number, carrier
designation, slot, and circuit of the maintenance object (MO) under test.
■
Maintenance Name: The type of MO tested.
■
Test Number: The actual test that was run.
■
Test Results: Indicates whether the test passes, fails, or aborts.
■
Error Code: Additional information about the results of the test. For
details, see
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...