EXP-INTF (Expansion Interface Circuit Pack)
Issue 1 May 2002
8-777
555-233-143
a. When the suspect Tone-Clock circuit pack resides in an in-service
pot network (PN) with duplicated Tone-Clock circuit packs:
Switch to the standby Tone-Clock in this PN. If the suspect
Tone-Clock is defective, the link(s) should be restored at this point.
(Switching back to the defective Tone-Clock should take the same
link(s) out of service.) This Tone-Clock is defective and should be
replaced as soon as possible. If switching Tone-Clocks does not
bring up the PN, then this Tone-Clock is not the source of the
problem. Be sure to switch back to the original Tone-Clock.
!
CAUTION:
If a defective Tone-Clock circuit pack is left as the standby
Tone-Clock, then a scheduled Tone-Clock switch will cause the
same link(s) go out of service again.
b. When the suspect Tone-Clock resides in an out-of-service PN:
Replace the active Tone-Clock circuit pack in this port network (PN).
In a PN with duplicated Tone-Clock circuit packs, the active
Tone-Clock’s amber LED is flashing. If both amber LEDs are
flashing, the active Tone-Clock’s LED is blinking slower.
!
CAUTION:
If a defective Tone-Clock circuit pack is left as the standby
Tone-Clock, then a scheduled Tone-Clock switch will cause the
same PN to go out of service again.
If replacing this circuit pack restores the link(s), then the circuit pack
should be replaced as soon as possible. If not, then it was not the
source of the problem.
Replacing an EI Circuit Pack—Unduplicated PNC
!
WARNING:
Do not power down a Switch Node carrier to replace a circuit pack.
!
WARNING:
Replacing a Switch Node Interface, Switch Node Clock, Expansion
Interface, or DS1 Converter circuit pack in a standard-, duplex-, or
high-reliability system disrupts service. This service effect can range from
an outage of a single PN to an outage of the entire system.
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...