DIOD-TRK (DIOD Trunk)
Issue 1 May 2002
8-573
555-233-143
DIOD-TRK (DIOD Trunk)
NOTE:
Many trunk problems are caused by incorrect settings of parameters on the
trunk group administration form. Settings must be compatible with the local
environment and with parameter settings on the far end. The Application
Notes section of that book shows the correct settings for administrable
timers and other parameters on a country-by-country basis.
Direct inward and outward dial (DIOD) trunks are 2-wire analog lines to the CO
which support the following services:
■
Both incoming and outgoing CO calls
■
DID trunk
■
DID trunk and 1-way outgoing DIOD
TN429 DIOD trunk circuit packs provide eight ports for loop-start CO trunks and
serve as an interface between the 2-wire analog CO line and the 4-wire TDM bus
on the switch.
MO’s Name (in
Alarm Log)
Alarm Level
Initial SAT Command to
Run
1
1.
UU is the universal cabinet number (1–64 for ATM PNC, 1–44 for CSS PNC). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot where the circuit pack resides (01–21).
pp is the 2-digit port number (01, 02, 03 ...).
Full Name of MO
DIOD-TRK
MAJOR
2
2.
A MAJOR alarm on a trunk indicates that alarms on these trunks are not downgraded by the set
options command and that at least 75 percent of the trunks in this trunk group are alarmed.
test port UUCSSpp l
DIOD Trunk
DIOD-TRK
MINOR
test port UUCSSpp l
DIOD Trunk
DIOD-TRK
WARNING
test port UUCSSpp l
DIOD Trunk
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...