There are three registers this test queries: the Optical Line receiver CRC error
register, the SDRAM single bit error register, and the SDRAM multiple bit error
register. The SDRAM single bit error register can be “self healed” by the DAJ1,
however, if there are chronic problems, it could be an indiction of a more serious
problem and should be noted. CRC errors indicate problems with the optical
interface between the Active and Standby connection. The SDRAM multiple bit
error condition will indicate that there is problems in the DAJ1 board’s memory,
multiple bit errors cannot be recovered. The following errors can be detected:
Table 8-195.
TEST Read Error Register Test
Error Code
Test
Result
Description / Recommendation
Open failed to
MDD
ABORT
The Memory Duplication Driver (MDD) is the system driver that
communicates with the DAJ1 board. If the driver cannot be
opened, then the DAJ1 board’s registers cannot be read. This is a
system type error, try again.
System Error MDD
failed to return
data
ABORT
The test ran, but, for some reason the MDD could not return data.
This is a system type error, try again.
DAJ1 err count
query, code=?
?= 1 to 7
FAIL
Test failed “DAJ1 err count query, code=?” – where “?” indicates
which of the DAJ1 board’s error counters had positive data. The
failure code can be 1–7 and is determined by the following bit
vector (all “x” bits could be set, indicating that every error register
had errors):
0xxx
If bit 1 is set (0xx1) – Single-bit errors occurred
If bit 2 is set (0x1x) – CRC errors occurred
If bit 3 is set (01xx) – Multibit errors occurred
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...