
CLAN-BD (Control LAN Circuit Pack)
Issue 1 May 2002
8-423
555-233-143
Invalid LAP-D Frame Error Counter Test (#597)
This test is nondestructive.
A C-LAN detects an invalid frame when it receives:
■
a frame with a CRC error
■
an unrecognizable frame
■
a recognizable frame in an unexpected state
When the C-LAN circuit pack detects an invalid LAP-D frame, it increments the
Invalid LAP-D Frame error counter. This test reads and clears the counter, and
verifies the repair of the problem.
Errors may indicate a:
■
circuit-pack problem
■
packet-bus problem
■
problem with another circuit pack on the bus
Table 8-171.
Test #597 Invalid LAP-D Frame Error Counter Test
Error
Code
Test
Result
Description / Recommendation
2000
ABORT
Did not receive circuit pack test response within the allowable time period.
1. Retry command at 1-minute intervals up to 5 times.
2. If the problem persists, reset the circuit pack (reset board UUCSS).
3. If the problem persists, replace the circuit pack.
2100
ABORT
Could not allocate the necessary system resources to run this test.
2500
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the problem persists, escalate the problem.
1–10
FAIL
The circuit pack detects LAP-D frame errors. The error code indicates the
value of the on-board error counter.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to fail, execute the Packet Interface test (#598) – test
board UUCSS long.
3. If the Packet Interface test (#598) fails, see
for repair procedures.
PASS
Circuit pack detects no errors.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...