Maintenance-Object Repair Procedures
555-233-143
8-302
Issue 1 May 2002
ATM-WSP (ATM WAN Spare
Processor)
S8700 Multi-Connect systems with multiple EPNs connected via ATM PNC have
the option of installing up to 15
ATM WAN Spare Processor (
WSP) units. Each WSP
has the ability to function as the S8700 Multi-Connect server, if the main server is
not functional or is not connected to one or more of the other EPNs.
ATM WSP is available in S8700 Multi-Connect standard loads. A WSP is capable
of running an entire S8700 Multi-Connect system (just as the main server can), or
whatever EPNs with which it can establish links while the ATM network is
impaired. WSPs continually monitor a path to the main server to determine
whether it is on-line. In the event of a main server failure, an automatic
switch-over to WSP control is neither instantaneous nor call-preserving. Likewise,
restoring the system to normal operation (under control of the main server)
requires manual intervention, and is neither instantaneous nor call preserving.
Each WSP attempts to establish connections (links) to every other WSP and to
the main server. These links are re-established once a minute. If a link cannot be
re-established, its status is flagged as “down.”
A WSP or main server is considered “down” if:
1. For standard reliability, links cannot be established on the A-PNC.
1. For a duplex- or high-reliability system and for standard reliability on the
other WSPs, links cannot be established:
— to both A-PNCs of the main server
— on the A-PNC between other WSPs
2. For a critical-reliability system, links cannot be established on both the
A- and B-PNCs.
A WSP becomes active (initiates a fail-over) when every link to a higher-priority
WSP and the main server has been in a “down” state for an administered amount
of time (as specified in the WSP Activation Timer field of the System-Parameters
Maintenance screen).
When a WSP becomes active, a major alarm is raised against this MO
(ATM-WSP). If it is later determined that the WSP should not be active, or the
system is rebooted at a COLD-2 or more severe level, the WSP is returned to a
standby state and the alarm retired. This alarm is never activated for the main
server.
MO’s Name
(in Alarm
Log)
Alarm Level
Initial Command to
Run
Full Name of MO
ATM-WSP
MAJOR
status atm wsp
ATM WAN Spare Processor
ATM-WSP
MINOR
status atm wsp
ATM WAN Spare Processor
ATM-WSP
WARNING
display atm wsp (1-15)
ATM WAN Spare Processor
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...