Chapter 5
CLI – Layer 2
Avaya
P333T-PWR User’s Guide
125
Note:
If you wish to define a name which includes spaces, you must enclose the
entire name in quotation marks, e.g. "new york".
rmon alarm
Use the
rmon alarm
command to create a new RMON alarm entry.
The syntax for this command is:
rmon alarm
<Alarm Number> <variable> <interval> <sampletype>
rising-threshold
<rising threshold> <rising event>
falling-
threshold
<falling threshold> <falling event> <startup alarm>
<owner>
alarm number
This is the alarm index number of this entry (it is advisable to
use the same interface number as your alarm index number.)
variable
This is the MIB variable which will be sampled by the alarm
entry.
interval
The interval between 2 samples.
sample type
This can be set to either
delta
(the difference between 2
samples) or an
absolute
value.
rising threshold
This sets the upper threshold for the alarm entry.
rising event
The RMON event entry that will be notified if the upper
threshold is passed.
falling
threshold
This sets the lower threshold for the alarm entry.
falling event
The RMON event entry that will be notified if the lower
threshold is passed.
startup alarm
The instances in which the alarm will be activated. The
possible parameters are:
Rising, Falling, risingOrfalling
.
owner
Owner name string.
Содержание P333R
Страница 1: ...Avaya User s Guide AVAYA P333R STACKABLE 3RD LAYER SWITCH SOFTWARE VERSION 3 11 July 2002 ...
Страница 2: ......
Страница 16: ...Table of Contents xiv Avaya P333R User s Guide ...
Страница 18: ...List of Figures xvi Avaya P333R User s Guide ...
Страница 20: ...List of Tables xviii Avaya P333R User s Guide ...
Страница 54: ...Chapter 4 CLI Architecture Access Conventions 34 P333R User s Guide ...
Страница 246: ...Chapter 7 Cajun Campus CLI Layer 3 226 Avaya P333R User s Guide ...
Страница 249: ...Appendix A Embedded Web Manager Avaya P333R User s Guide 229 The welcome page is displayed Figure A 1 The Welcome Page ...
Страница 266: ...Appendix B Specifications 246 Avaya P333R User s Guide ...