Avaya Communication Manager controlled maintenance
CO-DS1 (DS1 CO Trunk)
Maintenance of the Avaya G350 Media Gateway
89
June 2004
•
(i) Error Type 2562—Retry Failure error. This error is logged only. It is not a hardware failure and
hence does not start any testing or generate any alarms. This error comes from call processing and
is generated when a second attempt (retry) to seize an outgoing trunk fails.
•
(j) Error Type 2817—Glare error. This error is logged only. It is not a hardware failure and hence
does not start any testing or generate any alarms. This error is the result of a simultaneous seizure
of a two-way trunk from both the near-end and the far-end. Attempt to place the call again. If the
error persists, escalate.
•
(k) Error Type 3840—Port Audit and Update Test (#36) failed due to an internal system error.
Enter the
status trunk
command to verify the status of the trunk. If the trunk is out-of-service,
then enter the
release trunk
command to put it back into in-service. Retry the test command.
System Technician-Demanded Tests:
Descriptions and Error Codes
CAUTION:
Always investigate tests in the order they are presented in the table below when
inspecting errors in the system. By clearing error codes associated with the
NPE
Crosstalk Test, for example, you may also clear errors generated from other tests
in the testing sequence.
.
Table 43: Order of Investigation
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND*
NPE Crosstalk Test (#6)
Note: This Test ABORTS
X
ND
Conference Circuit Test (#7)
Note: This Test ABORTS
X
ND
DS1 CO Trunk Seizure Test (#314)
Note: This Test ABORTS
X
X
ND
Port Audit and Update Test (#36)
X
X
ND
*D = Destructive; ND = Nondestructive
Содержание Media Gateway G350
Страница 1: ...Maintenance of the Avaya G350 Media Gateway 555 245 105 Issue 3 June 2004 ...
Страница 16: ...About this book Sending us comments 16 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 48: ...G350 component maintenance IP telephones 48 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 284: ...Monitoring Extended keepalive 284 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 306: ...G350 traps G350 traps and resolutions 306 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 326: ...Media Server alarms S8300 alarms UPS 326 Maintenance of the Avaya G350 Media Gateway June 2004 ...