DIG-LINE Station Lamp Updates Test (#16)
This test lights all lamps on the terminal as specified. The lamp updates will run only if the station is in-
service. The status of the station is checked and the lamp updates are blocked from taking place if the
station is not in the in-service state. This test does not affect the status of the Message Waiting lamp.
Table 67: TEST #16 DIG-LINE Station Lamp Updates Test 1 of 2
Error
Code
Test
Result
Description/ Recommendation
ABORT
Internal system error
Retry the command at 1-minute intervals a maximum of 5 times.
1
ABORT
This port may have been busied out by system technician.
Look in the Error Log for Error Type 18 (port busied out) for this port. If
this error type is present, then release the port via the
release station
<extension>
command and run the test again.
Make sure that the terminal is connected.
Retry the command at 1-minute intervals a maximum of 5 times.
3
ABORT
Station may be in ready-for-service or out-of-service state.
Use
status station
command to verify state of station.
Make sure the terminal is connected.
Retry the command at 1-minute intervals a maximum of 5 times.
1000
ABORT
System resources required to run this test are not available. The port may be
busy with a valid call.
Use
display port GGGVSpp
to determine the station extension or
attendant number of the port. Use
status station
or
status attendant
to
determine the service state of the port. If the port is in use, wait until the
port is idle before testing. Attendants are always in use (off-hook) if the
handset is plugged in and the port is not busied out.
If the port status is idle, then retry the command at 1-minute intervals a
maximum of 5 times.
1392
ABORT
This port is currently a TTI port and the test will not execute on it.
Verify that the port is a TTI port using either the
display port
command
(the display shows that the port is a TTI port) or the
list config
command
(the display shows a “
t
” for the port).
If either
list config
or
display port
indicates that the port is not a TTI
port, escalate the problem. If both commands indicate that the port is a TTI
port, the abort is correct, and no action is necessary.
1 of 2
Содержание Media Gateway G350
Страница 1: ...Maintenance of the Avaya G350 Media Gateway 555 245 105 Issue 3 June 2004 ...
Страница 16: ...About this book Sending us comments 16 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 48: ...G350 component maintenance IP telephones 48 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 284: ...Monitoring Extended keepalive 284 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 306: ...G350 traps G350 traps and resolutions 306 Maintenance of the Avaya G350 Media Gateway June 2004 ...
Страница 326: ...Media Server alarms S8300 alarms UPS 326 Maintenance of the Avaya G350 Media Gateway June 2004 ...