PARTNER® Version, Installation and Reference Manual
Page 34
- Issue 1a (30 January 2010)
IP Office Essential Edition
Environmental Requirements
In addition to the existing
environmental requirements
for an IP Office system, the following additional factors must be
considered when rack mounting a unit:
1. Rack Positioning - Ensure compliance with the rack manufacturers safety instructions. For example check that the
rack legs have been lowered and fixing brackets have been used to stop toppling.
2. Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient
temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given
to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified
by the manufacturer.
·
Operating Temperature: 0°C (32°F) to 40°C (104°F).
·
Operating Humidity: 10% to 95% non-condensing.
3. Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for
safe operation of the equipment is not compromised. Proper ventilation must be maintained. The side ventilation
slots on the IP Office 500 control unit should not be covered or blocked.
4. Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not
achieved due to uneven mechanical loading.
5. Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and
the effect that overloading of the circuits might have on over-current protection and supply wiring. Appropriate
consideration of equipment nameplate ratings should be used when addressing this concern.
6. Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention should
be given to supply connections other than direct connections to the branch circuit (e.g. use of power strips).
7.
Only the screws (M3 x 6mm) provided with the mounting kit should used to attach the brackets to the control
unit.
Содержание IP Office Essential Edition PARTNER Version
Страница 2: ... Issue 1a 30 January 2010 PARTNER Version Reference IP Office Essential Edition ...
Страница 7: ......
Страница 13: ......
Страница 27: ...PARTNER Version Installation and Reference Manual Page 26 Issue 1a 30 January 2010 IP Office Essential Edition ...
Страница 45: ......
Страница 87: ......
Страница 105: ......
Страница 113: ......
Страница 117: ......
Страница 118: ...PARTNER Version Installation and Reference Manual Page 117 Issue 1a 30 January 2010 IP Office Essential Edition ...