CLI Commands
CNA test plugs
220 Avaya G450 CLI Reference
test-rate-limit
Use the
test-rate-limit
command to configure the CNA test rate limiter. The CNA test rate
limiter sets the maximum rate of tests that can be run by the CNA test plug embedded in the
G450. Use the
no
form of the command to return the CNA test rate limiter to its default
configuration.
Syntax
test-rate-limit
maxTests interval
Parameters
User Level
read-write
Context
cna-testplug
Example
To set the CNA test rate limit to 70 tests every 20 seconds:
G450-001(cna-testplug 1)# test-rate-limit 70 20
Related Commands
clear counters (CNA test plugs)
Parameter
Description
Possible
Values
Default
Value
maxTests
The maximum number of tests allowed in an interval.
Zero means no limit.
0-10000
60
interval
The rate limiter interval, in seconds
1-1000
10