Страница 2: ...TO BIND SUCH ENTITY TO THESE TERMS OF USE IF YOU DO NOT HAVE SUCH AUTHORITY OR IF YOU DO NOT WISH TO ACCEPT THESE TERMS OF USE YOU MUST NOT ACCESS OR USE THE HOSTED SERVICE OR AUTHORIZE ANYONE TO ACC...
Страница 3: ...CT TO CODECS IF THE AVAYA CHANNEL PARTNER IS HOSTING ANY PRODUCTS THAT USE OR EMBED THE G 729 CODEC H 264 CODEC OR H 265 CODEC THE AVAYA CHANNEL PARTNER ACKNOWLEDGES AND AGREES THE AVAYA CHANNEL PARTN...
Страница 4: ...gnments 16 Universal Serial Bus ports 17 Power specifications 18 Avaya Ethernet Routing Switch 4826GTS 4826GTS PWR 4850GTS and 4850GTS PWR 18 Power over Ethernet Plus power supply power specification...
Страница 5: ...r supplies for redundancy and load sharing Avaya Ethernet Routing Switch 4826GTS PWR 24 10 100 1000BaseTX RJ 45 ports with PoE 2 shared SFP ports and 2 10GE SFP ports Supports dual 1000W 54V power sup...
Страница 6: ...ing Avaya Ethernet Routing Switch 4000 Series is renamed Installing Avaya Ethernet Routing Switch 4800 Series Introduction chapter Information about Related resources and Support are moved to the last...
Страница 7: ...ile networking equipment is commonly designed and tested to withstand common mode ESD events voltage can sometimes discharge to some connector pins which can potentially damage the networking equipmen...
Страница 8: ...le RJ 45 connector of the ESD discharge cable for at least 5 seconds and then connect each RJ 45 cable connector to the switch 3 Leave cables connected to the networking equipment After you connect ca...
Страница 9: ...erference near the switch No excessive dust in the environment An adequate power source is within 6 feet 1 83 meters of the switch One 15 amp circuit is required for each power supply At least 2 inche...
Страница 10: ...cable 6 Documentation Note Cable trays can be provided as an option Installing the switch on a table or shelf You can install a single switch on any flat surface The surface must support the combined...
Страница 11: ...and shape Your switch might appear different than the following example figures 1 Attach the included rubber footpads on the bottom of the switch at the locations 2 Set the switch on a table or shelf...
Страница 12: ...Ohm of resistance from the rack to the grounding electrode Caution When you mount the device in a rack do not stack units directly on top of one another You must secure each unit to the rack with the...
Страница 13: ...The following table describes the cables required for ERS 4800 Table 3 Switch cable requirements Required Cable Description 10 100 1000Base TX Ports The interconnect cabling must conform to the Cat5e...
Страница 14: ...ables After you disable Autonegotiation on 10 100 ports MDI MDI x is also disabled Installation and removal of Small Form factor Pluggable transceivers The following section describes how to install a...
Страница 15: ...sceiver optical bores Removing of SFP transceivers Remove SFP transceivers by performing this procedure 1 Disconnect the network fiber cable from the transceiver 2 Use the locking mechanism on the tra...
Страница 16: ...Ethernet and Power over Ethernet Plus RJ 45 connector pin assignments in the Avaya ERS 4826GTS PWR and 4850GTS PWR Table 4 PWR PoE and PWR RJ 45 connector pin assignments Connector Pin Number Signal D...
Страница 17: ...binary configuration file The storage capacity of the USB device in use limits file and system operations Support is available only for USB drives that comply with the Mass Storage subsection of the...
Страница 18: ...pecifications 4826GTS 4826GTS PWR 4850GTS 4850GTS PWR Input Current 5A 2 5A 12A 6A 5A 2 5A 12A 6A Input Voltage rms 100 to 240VAC at 50 to 60 Hz 100 to 240VAC at 50 to 60 Hz 100 to 240VAC at 50 to 60...
Страница 19: ...0W Power over Ethernet Plus PoE AC power supplies Figure 3 1000W power supply The ERS 4826GTS and ERS 4850GTS support 300W AC power supplies Figure 4 300W power supply The 300W and 1000W AC power supp...
Страница 20: ...h one power supply Installing the switch power supply You must install at least one power supply before using the switch ERS 4800 models support two field replaceable internal power supplies If suppor...
Страница 21: ...power to the switch you need an appropriate AC power cord as described in the following table also see the following table for plug specifications Table 7 International power cord specifications Coun...
Страница 22: ...s statement see Translations of safety messages on page 45 Connect power to the back panel Connect the AC power cord to the back of the switch and then connect the cord to an AC power outlet The follo...
Страница 23: ...t finishes the power on self test Front panel LEDs The following diagrams illustrate the components on the front panels of the switch For detailed explanations of the states indicated by each front pa...
Страница 24: ...ove ports Figure 9 Avaya Ethernet Routing Switch 4850GTS 1 USB Port 4 Shared SFP ports and SFP ports SFP ports can support low speed 100FX SFP 2 Switch LEDs 5 Console Port 3 10 100 1000 ports LEDs abo...
Страница 25: ...ST is complete and the switch is operating normally After start up The switch is running the agent code successfully Green blinking The switch is loading the agent software code Amber solid The switch...
Страница 26: ...cates the level of activity on the link Link indicates the presence of an Ethernet link Speed indicates the port speed for example 10 Mb s 100 Mb s 1000 Mb s Table 9 RJ 45 Port LED state indicators La...
Страница 27: ...ber Blink Not applicable Amber Steady SFP Installed TX Port Inactive Off No SFP transceiver is present Link Activity Green Blink Activity exists on the port Green Slow Blink Software disabled this por...
Страница 28: ...cedure using the console port and CLI Quickstart 1 Connect a terminal to the console port of the switch You can use any terminal or PC with an appropriate terminal emulator as the management station T...
Страница 29: ...appears Please provide the in band IP Address 0 0 0 0 10 127 232 30 The in band sub net mask prompt line appears Please provide the in band sub net mask 0 0 0 0 255 255 255 0 The Default Gateway prom...
Страница 30: ...nd Command Line Interface CLI 1 Connect a terminal to the console port of the switch You can use a terminal or PC with an appropriate terminal emulator as the management station See Setting IP paramet...
Страница 31: ...rs in the ip cfg file All of the parameters are optional The following table describes the ip cfg file parameters Table 12 IP CFG file Parameter Description IP A B C D Specifies the IP address for the...
Страница 32: ...ip txt file Note The ip cfg file runs only on a base or stand alone unit The file cannot be more than 4096 bytes or contain more than 200 lines The following figure shows an example of an ip cfg file...
Страница 33: ...re to check the status of the download three minutes after the Avaya banner page appears 1 Press CTRL and y keys together Two possible responses indicate a pass or fail status Pass The system opens th...
Страница 34: ...rs on your browser 3 From the navigation tree double click Administration 4 In the Administration tree double click Quick Start The IP Community Vlan 5 In the IP Community Vlan work area type a switch...
Страница 35: ...nectivity for up to 400 ports You can manage the stack as a single unit Stack connector The stack connector is a component of the switch back panel and consists of the Unit Select switch Cascade Down...
Страница 36: ...unit to the Cascade Up connector of the first unit completes the stack connection See Figure 13 Connecting cascade cables on page 37 Important To create a stack connection order the appropriate switc...
Страница 37: ...the base unit within the stack Thereafter the individual units maintain their original unit numbering even if you change the position of one or more units in the stack For example when you initially p...
Страница 38: ...the stack it does not resume base unit status Also if the stack configuration loses power the temporary base unit does not resume base unit status when power is restored Important If the temporary ba...
Страница 39: ...he Cascade Up LED for Unit 4 turn amber to indicate an error The remaining stack units remain connected and continue to operate Replacing or adding a stack unit To replace a failed stack unit or inser...
Страница 40: ...g switch configuration settings revert to those configured before the unit became a member of the stack IP address Web Telnet and SNMP passwords SNMP community strings Stack configurations Because sta...
Страница 41: ...illustration demonstrates a typical cascade down stack down configuration Figure 15 Cascade Down Stack Down configuration Stack configurations August 2016 Installing Avaya ERS 4800 Series 41 Comments...
Страница 42: ...ase unit terminates in the Cascade Down connector of the last unit physically at the top of the stack The stack is wired upward through the units and the system continues to number in this manner thro...
Страница 43: ...Figure 16 Cascade Up Stack Up configuration Stack configurations August 2016 Installing Avaya ERS 4800 Series 43 Comments on this document infodev avaya com...
Страница 44: ...232 communications cable to the console port of any switch in the stack to establish a console connection You can perform a software upgrade on the stack from any switch using a Telnet session the We...
Страница 45: ...empilez pas directement sur un autre Chaque module doit tre fix sa propre baie l aide des supports de montage appropri s Ces supports ne sont pas con us pour r sister plusieurs modules Important Preca...
Страница 46: ...veillez laisser la plaque m tallique sur la baie Si vous la retirez l a ration du module ne peut pas s effectuer correctement Important Precaution Si no instala ning n m dulo en la ranura aseg rese d...
Страница 47: ...ment en cas d urgence Important Advertencia Para apagar el dispositivo debe desenchufar el cable Conecte siempre el cable de alimentaci n a una toma segura y de f cil acceso por si se produjera alguna...
Страница 48: ...cessives Important Peligro Utilice nicamente cables de alimentaci n con toma de tierra De lo contrario al tocar el interruptor puede recibir una descarga el ctrica Si no hay un circuito de toma de tie...